background image

5

Introduction - Networking the RAVE 522ua

The RAVE 522ua has two RJ-45 network connection ports on the rear panel. One port is labeled "QSControl" and supports standard 
10BASE-T Ethernet.  The other port is labeled "CobraNet" and supports 100BASE-TX, also known as "Fast Ethernet". In the following 
sections, we describe the use of these ports and show example network connection schemes.

The RAVE 522ua supports two distinct kinds of network activity; the first is audio transport via CobraNet, and the second is QSCon-
trol.net. The user can choose to install one network for CobraNet traffic and a second separate network for QSControl.net traffic. We 
call this the "Two Wire Interface". Alternately, it is possible to run both QSControl.net data and audio traffic via the CobraNet port. In 
this case the QSControl port is unused. We call this the "Single Wire Interface".

Under the most demanding real-time control conditions and when using the lowest latency CobraNet settings, users may experience 
better QSControl.net performance using separate networks, especially when displaying a great many real-time meters. For most appli-
cations, separate networks won't provide any discernible benefits and will cost more. We therefore recommend using the Single Wire 
Interface when running CobraNet. 

If your application uses only analog I/O without CobraNet, then you should use the QSControl port for QSControl.net traffic and ignore 
the CobraNet port.

Why CobraNet Needs Special Treatment:

Ordinary Ethernet traffic has no guaranteed time of delivery. Packets of information may arrive at their destination out of order and 
some may be delayed more than others. This is fine for E-mail and even for downloading MP3 files over the Internet. Everything ends up 
properly reassembled at the destination, but how long this takes will vary according to network loading, span, etc. In contrast, Cobra-
Net is "real time" - it delivers audio with a minimal, consistent transmission delay. CobraNet is designed to use as much of conventional 
networking technology as possible while providing both guaranteed time of delivery and isochronicity - maintaining a phase-locked 
sample-accurate clock across the entire network. These requirements mean that ordinary unregulated Ethernet data cannot be freely 
mixed with CobraNet information. The two can coexist on the same wire, but only by adhering to the proper rules.

To learn more about CobraNet and appropriate network topologies, please visit http://www.qscaudio.com/products/network/
resources.htm and http://www.peakaudio.com/CobraNet/background.html.

Notes on Network Systems Design:

As with any communications system, the reliability and performance of a local area network is intimately related to the designer's skill 
and knowledge in implementing a topology that is robust, efficient and standards-compliant. Proper network design is even more criti-
cal in distributed multimedia systems. Therefore, it is important for the system designer to realize that some conventional network 
practices must be avoided. Although each network design is unique and may carry its own performance requirements, compliance to 
the following three points will assist in building an audio network that is trouble free and efficient. 

First, audio and conventional data communications deliveries should not exist on the same LAN or VLAN. The exception to this is the 
RAVE 522ua Single Wire Interface, which offers a solution for converging audio and QSControl.net onto the same LAN or VLAN. How-
ever, conventional communications, such as corporate networks, print services, e-mail and Internet access, should not exist alongside 
CobraNet audio and QSControl.net on the same LAN or VLAN. Further, CobraNet audio and QSControl.net data should not exist 
together on the same LAN or VLAN when implementing the Two Wire Interface. This is not to say that conventional communications 
cannot share the same network hardware with a RAVE 522ua. In fact, common network hardware, such as managed Ethernet switches 
and media converters, can service both RAVE 522ua products and conventional data communications equipment so long as the man-
aged switch or media converter are partitioned into separate network domains. This is normally done by configuring a separate VLAN 
for each data type. (Some switches may allow individual port assignments or support partitions through DIP switch selection.)

Second, CobraNet audio must traverse either a repeater domain or a network switch domain. The point here is that the CobraNet port 
on a RAVE 522ua must connect directly to, and only to, either a repeater LAN or a switched Ethernet LAN. Hybrid networks containing 
both repeaters and switches are not permitted on the audio segment. Connecting the CobraNet port to a repeater that is in turn con-
nected to a network switch poses an illegal and non-compliant condition. We recommend always connecting the QSControl and/or 
CobraNet port(s) directly to network switch ports. 

Summary of Contents for RAVE 522ua

Page 1: ...TD 000198 00 rev A TD 000198 00 RAVE 522ua 8x8 CobraNet Enabled Signal Processor Hardware Manual...

Page 2: ...ord 5 Reliable Earthing Grounding of rack mounted equipment should be maintained LITHIUM BATTERY WARNING THIS EQUIPMENT CONTAINS A NON RECHARGEABLE LITHIUM BATTERY LITHIUM IS A CHEMICAL KNOWN TO THE S...

Page 3: ...at the same time from anywhere a connection to the QSControl net network is available The QSControl net network can also be managed from a sin gle computer running both the client and the server Once...

Page 4: ...will be adding new capabilities to both RAVE and QSControl net Our latest code releases and access to up to date information on RAVE and QSCon trol net are available at www qscontrol net We invite yo...

Page 5: ...er rules To learn more about CobraNet and appropriate network topologies please visit http www qscaudio com products network resources htm and http www peakaudio com CobraNet background html Notes on...

Page 6: ...is a TCP IP standards compliant network system and therefore supports operation on network repeaters switches and routers When implementing the Two Wire Interface the QSControl net segment does not r...

Page 7: ...out a network switch However you would have to physically connect your computer first to one unit and then to the other With this elementary connection you don t have a true network It is like making...

Page 8: ...figuration works well when CobraNet audio deliveries are point to point Though the example shows only two RAVE BASIS units as many devices may be connected as there are available switch ports All unit...

Page 9: ...VLAN for QSControl net traffic and a separate VLAN for CobraNet audio traffic This config uration essentially provides a dedicated network for QSControl net including the system controller and a secon...

Page 10: ...ith its own network switch Therefore traffic segmentation is physical rather than logical Example 5 also pro vides an additional level of fault tolerance although at the expense of additional network...

Page 11: ...pment rack Rack mounting is optional Adhesive rubber feet are included for non rack mount installations Use them to prevent the unit from scratching or marring support surfaces Rack Mounting Rack moun...

Page 12: ...ystem is used for real time adjustments and configuration of audio systems we recommend all Windows Power Options located in the Windows Control Panel features be disabled Display hard drive system st...

Page 13: ...ily mute allow ing the RAVE 522ua to synchronize with its internal clock If CobraNet network connection is re established the audio will mute again while the RAVE 522ua synchronizes with CobraNet Conf...

Page 14: ...Use balanced audio inputs whenever possible Each input has software selectable 48V phantom power Use caution when connecting equipment par ticulary unbalanced equipment Analog Outputs Eight balanced...

Page 15: ...unctioning AC outlet it will power up and briefly display a welcome screen on the LCD dis play POWER Indicator This blue indicator illuminates when the RAVE 522ua is plugged into a properly functionin...

Page 16: ...ept knob is active for many displayed items allowing you to scroll through choices by rotating the control and accepting choices entering by pushing in on the control The accessible menus and sub menu...

Page 17: ...creen accessed becomes the new power up default Boot Screen Right side buttons serve as up down navigation Arrow characters indicate right side button context If additional menus are available the arr...

Page 18: ...cify the installation directory or accept the default location 9 You will be prompted to select an installation accessible by everyone non secure or an installation accessible only to you secure Selec...

Page 19: ...verify IP addresses are set correctly verify Subnet masks are set correctly and verify AC power is properly applied to the RAVE 19 Click on the sign of the RAVE 522ua in the inventory root then the si...

Page 20: ...ork This is currently 16 bit 20 bit and 24 bit Audio via inbound bundles may be in any combination of these resolu tions and the RAVE will process the data accordingly All DACs will process 24 bit aud...

Page 21: ...icate with the RAVE 522ua if it is in safe mode You may communicate only using TFTP Telnet or RS 232 RS 232 Serial Port I O Interface The RS 232 connector on the rear panel is used as a serial port in...

Page 22: ...click OK to continue If all the connections and communications settings are correct the main Hyper Terminal window will open 6 The Hyper Terminal main window will appear next but blank Type the letter...

Page 23: ...opening a Telnet session 1 To open the Telnet session Click START select RUN type Telnet followed by a space then the IP address of the RAVE 522ua you want to communicate with in the text box and cli...

Page 24: ...put Sensitivities variable Vrms 0 9 mV to 15 46 V dBu 62 2 to 26dBu dBV 64 4 to 23 7 dBV Phantom Power per IEC 1938 1996 48V software selectable Program Outputs 8 Connector Type 3 pin Phoenix Style a...

Page 25: ...nd referenced Pinout 1 Signal 2 CHASSIS GND Normal Operating Range Reads signals between 0 5V nominally Potentiometer Operation Use 10K for full range Voltage Tolerance 48V Current Output 0 5mA with 1...

Page 26: ...26 Dimensions...

Page 27: ......

Page 28: ...suppliers be held liable for any damages consequential incidental or otherwise including any claims for lost profits and or savings resulting from any attempted integration of QSControl products with...

Reviews: