13
EN
EN
TD-000367-00-A
— Figure 16 —
F8: AB+CD
F8: AB+CD
AB Parallel
Bridged with
CD Parallel
The following are electrically
the same point
T1+and T3+
T5- and T7-
M AB+CD
Two-Channel Configurations
— Figure 17 —
F6: A+B C+D
F6: A+B C+D
A+B Bridged
C+D Bridged
A+B
C+D
M
M
— Figure 18 —
F5: AB C+D
F5: AB C+D
AB Parallel
C+D Bridged
AB
C+D
M
M
The following are electrically
the same point
T1+ and T3+
T2- and T4-
— Figure 19 —
F4: AB CD
F4: AB CD
The following are electrically
the same point
T1+ and T3+
T5+ and T7+
T2- and T4-
T6- and t8-
AB Parallel
CD Parallel
AB
CD
M
M