13
14
Speakon™ Outputs
CMX amplifiers offer a choice of output connections, with two Neutrik NL4MD Speakon™ jacks and a Terminal Block connector.
The Speakon™ connector is designed specially for high-power speaker connections. It locks in place, prevents shock hazard, and assures the
correct polarity.
The upper Speakon™ jack has both Channel 1 and Channel 2 outputs, so it is especially useful for Parallel, bi-amp, or Bridge Mono mode operation
(see Bridge Mono mode operating precautions on page 7). The other Speakon™ carries only the output from Channel 2.
For easier insertion, use the newer-style NL4FC Speakon™ connectors with quick-lock thumb latches
(Not shown)
.
Speaker Cabling
Larger wire sizes and shorter lengths minimize both loss of power and degradation of damping factor. Do not place speaker cables next to
input wiring.
WARNING: To prevent electric shock, do not operate the amplifier with any of the conductor portion of the speaker wire exposed.
2 channels & 2 Speakon™ connectors
(Stereo, bi-amp, or parallel mode)
2 channels & 1 Speakon™ connectorss
(Stereo, bi-amp, or parallel mode)
Bridge Mono mode
To Channel 1 speaker
To Channel 2 speaker
To Channel 1 speaker
To Channel 2 speaker
Channel 1
Channel 2
To speaker
– Figure 27 –
– Figure 28 –
– Figure 29 –
Summary of Contents for CMX500V
Page 1: ...User Manual CMX 300V CMX 500V CMX 800V CMX Series TD 000322 00 TD 000322 00...
Page 21: ...Manuel d utilisation CMX 300V CMX 500V CMX 800V S rie CMX TD 000322 00 TD 000322 00...
Page 41: ...Benutzerhandbuch CMX 300V CMX 500V CMX 800V Serie CMX TD 000322 00 TD 000322 00...
Page 61: ...CMX 300V CMX 500V CMX 800V CMX TD 000322 00 TD 000322 00...
Page 66: ...5 LF 30 Hz 50 Hz 6 7 DIP 4 5 5 Hz DC 50 Hz 100 Hz 30 Hz 4 5 6 7...
Page 67: ...6 Y 4 5 8 9 8 9...
Page 68: ...7 1 2 DIP OFF 10 11 8 4 6 7 10 1 12 13 100 RMS CMX 800V CLASS 3 NEC 1999 2 8 10 10 11 12 13...
Page 69: ...8 DIP 14 15 1 2 1 2 1 16 1 DIP 17 16 Ch 2 15 17 16 2 14...
Page 70: ...9 8 4 7 4 8 2 4 AC 4 2 2 DIP 18 7 2 DIP 8 10 18...
Page 77: ...16 4 8 2 LED 4 4 LED LED LED LED 34...
Page 78: ...17 LED LED LED LED OFF...
Page 81: ...Manual del usuario CMX 300V CMX 500V CMX 800V Serie CMX TD 000322 00 TD 000322 00...