background image

3

Introduction

1- Power indicator
2- Diagnostic indicator
3- Network status indicators
4- Port connection status indicators
5- Multi-function push buttons
6- Display
7- Rotary select/accept knob
8- Safe Mode switch (recessed)
9- DataPorts

10- AES/EBU inputs
11- Monitor chain in/out 
12- Relay outputs
13- Logic outputs
14- Omni inputs
15- RS-232 port
16- Network status indicators
17- QSControl 10BaseT receptacle
18- CobraNet 100BaseT receptacle
19- IEC power inlet

The BASIS 922dz provides the digital audio transport, signal 
processing, control and status monitoring facilities needed 
to bind a group of amplifiers and loudspeakers into an inte-
grated functioning system. In conjunction with QSCon-
trol.net software, the BASIS 922dz enables the user to 
design, test and deploy professional audio reinforcement 
and distribution systems ranging in size from one to hun-
dreds of channels. 

Each QSC power amplifier connects directly to a BASIS 
922dz via one of its four QSC DataPorts. All mission-critical 
elements of the BASIS-driven sound system are monitored. 
User-selected events are logged and loudspeaker protection 
features unique to BASIS such as QSC's power limiter are 
made possible through the DataPort functionality.

A standard Windows computer is the principle user-inter-
face for controlling the overall BASIS/QSControl.net sys-
tem. However, the BASIS 922dz also offers a front panel 
interface for accessing a few critical functions. 

A single QSControl.net server computer can support several 
clients running QSC's latest Venue Manager software. Thus, 
the sound system can be operated via several computers, 
roaming wireless laptops, tablets, etc., all at the same time, 

from anywhere a connection to the QSControl.net network 
is available. 

The QSControl.net network can also be managed from a sin-
gle computer running both the client and the server. Once all 
BASIS devices in a system are configured, a computer is no 
longer required on that system’s network. All basic func-
tions of the BASIS 922dz continue to operate with or with-
out a control computer connected to the network.

The configurable DSP engine provides all of the functions 
necessary to handle the amp/loudspeaker portion of a sig-
nal chain, such as very flexible and precise crossovers, 
delays, equalization, compression/limiting, etc. 

Audio enters a BASIS 922dz either through AES/EBU digital 
inputs or from CobraNet source devices such as QSC's line 
of RAVE digital audio routers. Any combination of 16 Cobra-
Net channels (selected from up to 4 bundles of 32 channels) 
can be routed into the 24 x 24 DSP engine. Any or all of the 
24 DSP channels can also be routed to up to 32 CobraNet 
channels on the network.

Unlike other configurable DSP boxes, the intrinsic process-
ing latency of the BASIS 922dz is both short and fixed at 

See page 14 for detailed descriptions.

Don’t want to read the entire manual? Just 
want to dig right in? Go to page 18....

Summary of Contents for BASIS 922dz

Page 1: ...TD 000202 00 rev B TD 000202 00 BASIS 922dz 8x8 CobraNet Enabled Control and Monitoring Signal Processor Hardware Manual...

Page 2: ...d 5 Reliable Earthing Grounding of rack mounted equipment should be maintained LITHIUM BATTERY WARNING THIS EQUIPMENT CONTAINS A NON RECHARGEABLE LITHIUM BATTERY LITHIUM IS A CHEMICAL KNOWN TO THE STA...

Page 3: ...22dz also offers a front panel interface for accessing a few critical functions A single QSControl net server computer can support several clients running QSC s latest Venue Manager software Thus the...

Page 4: ...asily updated over the network In the future QSC will be adding new capabilities to both BASIS and QSControl net Our latest code releases and access to up to date information on BASIS and QSCon trol n...

Page 5: ...ing to the proper rules To learn more about CobraNet and appropriate network topologies please visit http www qscaudio com products network resources htm and http www peakaudio com CobraNet background...

Page 6: ...loyments QSControl net is a TCP IP standards compliant network system and therefore supports operation on network repeaters switches and routers When implementing the Two Wire Interface the QSControl...

Page 7: ...would have to physically connect your computer first to one BASIS box and then to the other With this elementary connection you don t have a true network It is just like making RS 232 connections exc...

Page 8: ...riate destination anywhere on the network Though the example shows only two BASIS 922dz units as many devices may be connected as there are available switch ports All BASIS units will be able to commu...

Page 9: ...ol net traffic and a separate VLAN for CobraNet audio traffic This config uration essentially provides a dedicated network for BASIS 922dz control and monitoring including the system controller and a...

Page 10: ...ith its own network switch Therefore traffic segmentation is physical rather than logical Example 5 also pro vides an additional level of fault tolerance although at the expense of additional network...

Page 11: ...r out of an equipment rack Rack mounting is optional Adhesive rubber feet are included for non rack mount installations Use them to prevent the unit from scratching or marring support surfaces Rack Mo...

Page 12: ...ws 95 98 and ME platforms are not supported Note If system is used for real time adjustments and configuration of audio systems we recommend all Windows Power Options located in the Windows Control Pa...

Page 13: ...ntroller computer CobraNet Connection Loss If you are operating with a valid CobraNet network and the connection to the network is disrupted audio will momentarily mute allow ing the BASIS 922dz to sy...

Page 14: ...ccept contact closure TTL logic signals 0 5 VDC control voltages or 10k ohm variable resistors The contact closure and logic devices accommodate on off or state change events the variable resistor inp...

Page 15: ...table combinations If connecting a multi DataPort amplifier be sure to connect all the DataPorts to the same BASIS This practice assures proper amplifier reporting in QSControl net To connect the cabl...

Page 16: ...of the display are used to navigate through the menus The rotary select accept knob is active for many displayed items allowing you to scroll through choices by rotating the control and accepting cho...

Page 17: ...irst setting up a network system Once user moves to a different screen the last screen accessed becomes the new power up default Boot Screen Right side buttons serve as up down navigation Arrow charac...

Page 18: ...ecify the installation directory or accept the default location 9 You will be prompted to select an installation accessible by everyone non secure or an installation accessible only to you secure Sele...

Page 19: ...applied to the BASIS 19 Click on the sign of the BASIS 922dz in the inventory root then the sign of the Flashed Configs Click on the config with the loudspeaker icon A view of applicable device tabs w...

Page 20: ...lu tion off of the network This is currently 16 bit 20 bit and 24 bit Audio via inbound bundles may be in any combination of these resolu tions and the BASIS will process the data accordingly All DACs...

Page 21: ...unicate with the BASIS 922dz if it is in safe mode You may communicate only using TFTP Telnet or RS 232 RS 232 Serial Port I O Interface The RS 232 connector on the rear panel is used as a serial port...

Page 22: ...d click OK to continue If all the connections and communications settings are correct the main Hyper Terminal window will open 6 The Hyper Terminal main window will appear next but blank Type the lett...

Page 23: ...opening a Telnet session 1 To open the Telnet session Click START select RUN type Telnet followed by a space then the IP address of the BASIS 922dz you want to communicate with in the text box and cli...

Page 24: ...ES EBU sample rate must be 48KHz and is internally synchronized Program Outputs 8 Connector Type 4 HD 15 dataport connections Cable Type QSC DataPort cable QSC p n DPC x x designates cable length in f...

Page 25: ...onnector Type 2 pin Phoenix Style a k a Euro Style detachable terminal blocks Configuration Single ended TTL compatible Pinout 1 Signal 2 CHASSIS GND Omni Inputs 6 discrete inputs for TTL logic voltag...

Page 26: ...26 Dimensions...

Page 27: ......

Page 28: ...ts suppliers be held liable for any damages consequential incidental or otherwise including any claims for lost profits and or savings resulting from any attempted integration of QSControl products wi...