background image

14

Connections

AC Power Cord

Insert the molded receptacle of the AC power cord into the AC power inlet on the 
back of the BASIS 922dz. Plug the AC line connector into the AC outlet. The power 
supply will accept from 100 to 240 Volts AC, 47 to 440 Hertz, without any changes. 
If a different type of IEC power cord is required than supplied with your 922dz, con-
tact QSC’s Technical Services Department.

CobraNet

Connect one end of a category-5 cable terminated with a RJ45 plug into the 

CobraNet

 receptacle. Insert the RJ45 plug into the receptacle with the lock-tab 

oriented toward the bottom of the BASIS 922dz and push firmly until the connector 
locks into place (usually an audible “click” can be heard). Connect the other end to 
the appropriate CobraNet network port.

QSControl

Connect one end of a category-5 cable terminated with an RJ45 plug into the 

QSControl

 receptacle. Insert the RJ45 plug into the receptacle with the lock-tab 

oriented toward the bottom of the BASIS 922dz and push firmly until the connector 
locks into place (usually an audible “click” can be heard). Connect the other end to 
the appropriate QSControl.net network port.

Digital Audio Inputs

Four pair of AES/EBU inputs are provided through a DB-25 style connector. Connec-
tion pin-out is printed on the rear label for reference. AES/EBU sample rate must 
be 48KHz and is internally synchronized.

Omni In

The

 

six

 Omni In

 

connectors are two-pin terminal block connectors. They accept 

contact closure, TTL logic signals, 0-5 VDC control voltages, or 10k ohm variable 
resistors. The contact closure and logic devices accommodate on/off or state-
change events; the variable resistor input provides full 8-bit resolution allowing for 
incremental-change events. Refer to the illustrations for connection recommenda-
tions. NOTE! +48 volts is the absolute maximum that can be applied to the + pin 
without damage. Voltage is with respect to chassis or the - pin.

Logic Out

The

 

four 

Logic Out

 

connectors are two-pin terminal block connectors. They pro-

vide CMOS logic level compatible signals for external devices.

Relay Out

Two sets of relay contacts are provided, 

RELAY OUT 1

 and 

RELAY OUT 2

. Con-

tacts are floating and rated for 30VDC, 1A. There is one common terminal, one nor-
mally-closed contact terminal and one normally-open contact terminal. These are 
labeled as 

C, NC

 and 

NO

 on the rear panel. When the relay is not energized, the

 

C

 

terminal is connected to the 

NC

 terminal and the 

NO

 

terminal is not connected; 

when the relay is energized the 

C

 to 

NC

 connection is opened and the 

to 

NO

 con-

nection is closed. 

AES/EBU digital input 
connector and pinout.

Relay Out connec-
tions. Refer to text, 
at left, for explana-
tion.

Logic Out connections. 
Negative (-) terminal is 
at chassis potential. 
Positive (+) terminal 
logic level is switched 
using software.

CobraNet and 
QSControl con-
nection. Accepts 
ruggedized or 
normal shell-less 
RJ45 plugs.

Omni In connec-
tions. Variable 
input must be 10k 
ohm variable 
resistor. Contact 
closure input can 
be a switch or 
relay contacts. 
These inputs can 
operate software 
“devices”. Nega-
tive (-) terminal is 
at chassis poten-
tial.

Summary of Contents for BASIS 922dz

Page 1: ...TD 000202 00 rev B TD 000202 00 BASIS 922dz 8x8 CobraNet Enabled Control and Monitoring Signal Processor Hardware Manual...

Page 2: ...d 5 Reliable Earthing Grounding of rack mounted equipment should be maintained LITHIUM BATTERY WARNING THIS EQUIPMENT CONTAINS A NON RECHARGEABLE LITHIUM BATTERY LITHIUM IS A CHEMICAL KNOWN TO THE STA...

Page 3: ...22dz also offers a front panel interface for accessing a few critical functions A single QSControl net server computer can support several clients running QSC s latest Venue Manager software Thus the...

Page 4: ...asily updated over the network In the future QSC will be adding new capabilities to both BASIS and QSControl net Our latest code releases and access to up to date information on BASIS and QSCon trol n...

Page 5: ...ing to the proper rules To learn more about CobraNet and appropriate network topologies please visit http www qscaudio com products network resources htm and http www peakaudio com CobraNet background...

Page 6: ...loyments QSControl net is a TCP IP standards compliant network system and therefore supports operation on network repeaters switches and routers When implementing the Two Wire Interface the QSControl...

Page 7: ...would have to physically connect your computer first to one BASIS box and then to the other With this elementary connection you don t have a true network It is just like making RS 232 connections exc...

Page 8: ...riate destination anywhere on the network Though the example shows only two BASIS 922dz units as many devices may be connected as there are available switch ports All BASIS units will be able to commu...

Page 9: ...ol net traffic and a separate VLAN for CobraNet audio traffic This config uration essentially provides a dedicated network for BASIS 922dz control and monitoring including the system controller and a...

Page 10: ...ith its own network switch Therefore traffic segmentation is physical rather than logical Example 5 also pro vides an additional level of fault tolerance although at the expense of additional network...

Page 11: ...r out of an equipment rack Rack mounting is optional Adhesive rubber feet are included for non rack mount installations Use them to prevent the unit from scratching or marring support surfaces Rack Mo...

Page 12: ...ws 95 98 and ME platforms are not supported Note If system is used for real time adjustments and configuration of audio systems we recommend all Windows Power Options located in the Windows Control Pa...

Page 13: ...ntroller computer CobraNet Connection Loss If you are operating with a valid CobraNet network and the connection to the network is disrupted audio will momentarily mute allow ing the BASIS 922dz to sy...

Page 14: ...ccept contact closure TTL logic signals 0 5 VDC control voltages or 10k ohm variable resistors The contact closure and logic devices accommodate on off or state change events the variable resistor inp...

Page 15: ...table combinations If connecting a multi DataPort amplifier be sure to connect all the DataPorts to the same BASIS This practice assures proper amplifier reporting in QSControl net To connect the cabl...

Page 16: ...of the display are used to navigate through the menus The rotary select accept knob is active for many displayed items allowing you to scroll through choices by rotating the control and accepting cho...

Page 17: ...irst setting up a network system Once user moves to a different screen the last screen accessed becomes the new power up default Boot Screen Right side buttons serve as up down navigation Arrow charac...

Page 18: ...ecify the installation directory or accept the default location 9 You will be prompted to select an installation accessible by everyone non secure or an installation accessible only to you secure Sele...

Page 19: ...applied to the BASIS 19 Click on the sign of the BASIS 922dz in the inventory root then the sign of the Flashed Configs Click on the config with the loudspeaker icon A view of applicable device tabs w...

Page 20: ...lu tion off of the network This is currently 16 bit 20 bit and 24 bit Audio via inbound bundles may be in any combination of these resolu tions and the BASIS will process the data accordingly All DACs...

Page 21: ...unicate with the BASIS 922dz if it is in safe mode You may communicate only using TFTP Telnet or RS 232 RS 232 Serial Port I O Interface The RS 232 connector on the rear panel is used as a serial port...

Page 22: ...d click OK to continue If all the connections and communications settings are correct the main Hyper Terminal window will open 6 The Hyper Terminal main window will appear next but blank Type the lett...

Page 23: ...opening a Telnet session 1 To open the Telnet session Click START select RUN type Telnet followed by a space then the IP address of the BASIS 922dz you want to communicate with in the text box and cli...

Page 24: ...ES EBU sample rate must be 48KHz and is internally synchronized Program Outputs 8 Connector Type 4 HD 15 dataport connections Cable Type QSC DataPort cable QSC p n DPC x x designates cable length in f...

Page 25: ...onnector Type 2 pin Phoenix Style a k a Euro Style detachable terminal blocks Configuration Single ended TTL compatible Pinout 1 Signal 2 CHASSIS GND Omni Inputs 6 discrete inputs for TTL logic voltag...

Page 26: ...26 Dimensions...

Page 27: ......

Page 28: ...ts suppliers be held liable for any damages consequential incidental or otherwise including any claims for lost profits and or savings resulting from any attempted integration of QSControl products wi...