Quick Maintenance
61
Push the PSU all the way into the empty slot until you hear the “click” sound from the
release tab.
Figure 6-7
Installing the Power Supply Unit in the System Chassis
If the PSU is successfully installed, the status L
ED will show solid
green
color (if no other
malfunction is encountered)
.
6.3.
Removing / Installing the Fan Module
The standard XCubeDAS system comes with two redundant fan modules that allow you to
hot swap it when one of the fan modules encounters an issue. In the event that the fan
module fails, it can be hot-swapped. The XCubeDAS series utilizes two types of fan module
for 4U/3U and 2U system chassis. Please refer to the following information for the fan
module removing / installing procedures.
CAUTION:
The fan module is heavy; please use both hands while removing, holding,
or carrying the fan module. The fan module is hot swappable, but power
off the system to do the fan module installing or removing is highly
recommended. Recommended place for installing / removing a fan
module: the system is on the well secured rack or onto stable surface.