Reason 4
Bad SCSI cabling. It is recommended that you always use high-
quality “premium” SCSI cables to eliminate data corruption, parity
errors and other problems. “Premium” can be defined as double-
shielded, layered twisted pair with 25 wire pairs, single-ended
impedance of 80-110 ohms, and molded.
Step 1: Turn off the power to your PC and all peripherals.
Step 2: If possible, verify that all SCSI external cables are “premium” and
remove all non-premium external SCSI cables.
Step 3: If you are unsure of the quality of the cables you are using, disconnect
all cables and peripherals from your system. Use the supplied cable
to attach the CD-R Drive and power on all peripherals and then your PC.
Step 4: If everything boots up fine, power off the PC and all peripherals,
and begin attaching another cable and peripheral to your system.
Step 5: Repeat Step 4 until you have a problem. When a problem exists,
try using a different SCSI cable and repeat Steps 4 and 5 until you
can rule out all possible bad cables by the process of elimination.
23
Questions
Summary of Contents for Que!
Page 1: ......
Page 4: ...Notes...
Page 6: ...2 Notes...
Page 22: ...18 Notes...
Page 32: ...28 Notes...
Page 34: ...Notes 30...
Page 37: ......
Page 38: ......
Page 39: ......
Page 40: ......
Page 41: ......