Running Procedure
Part3-6
CHECKING ALARM LEVELS AND READING CHANNELS
TO CHECK ALARM LEVEL SETTING
To check the pre-set alarm level setting for each individual channel, first place the
magnetic pen over the circle marked ‘ALARM LEVEL’. The alarm level indicator will
illuminate. Place the pen over the ‘CHANNEL’ number. The channel identification digital
display will be shown digitally as a milligrams per litre value in mg/L of oil mist density.
Should the alarm level need to be adjusted then follow the ‘Initial Setting-up Procedure’
(changing alarm levels) and ‘RESET’ the system as previously described.
TO READ INDIVIDUAL CHANNELS
Place the magnetic pen over the required channel circle. The channel number selected
will be shown digitally on the ‘Channel Identification’ display alongside the digital read-
out of the percentage density of the pre-set alarm level at the channel. After one
minute the display will revert to the channel with the highest oil mist reading.