QMD Install manual D06400210010G PTZ Dome Camera
44
Alarm-ON Management Protocol
With the presetting of its internal software, the PTZ camera will perform the
following functions automatically at the triggering(s) to alarm-input(s):
Camera is running Auto-pan when alarm signal(s) kicks in
1. When the first alarm signal hits this camera, lens will move to the
corresponding presets
(see relative information on above)
at maximum speed
of 240
o
per second
2. Lens will stay at the preset position for 60 seconds
3. Camera will be back to the original auto-pan function after 60 seconds, if
no second alarm-in jumps in this 60 second time frame.
4. In case another or more alarm signals are in during 60 seconds, camera
will move to the corresponding preset(s) and stay for 10 seconds initially,
then move to the next alarm-preset for 5 seconds and keeps the same
movement in sequence until the 60 second time segment is over.
5. Camera will be back to its original auto-pan function after the 60 seconds.
Camera is in still mode when alarm signal(s) kicks in
1. When the first alarm signal hits this camera, lens will move to the
corresponding presets
(see relative information on above )
at maximum speed
of 240
o
per second
2. Lens will stay at the preset position for 60 seconds
3. Camera will be back to the original position after 60 seconds, if no second
alarm-in jumps in this 60 second time frame.
4. In case another or more alarm signals are in during 60 seconds, camera
will move to the corresponding preset(s) and stay for 10 seconds initially,
then move to the next alarm-preset for 5 seconds and keeps the same
movement in sequence until the 60 second time segment is over.
5. Camera will be back to its original position after the 60 seconds.
Note:
All the three alarm inputs are TTL level and triggered by negative signals.
To utilize the default view positions, user must pre-set the desired monitor
spots to presets number 17, 18, 19, 20, 21, 22, 23 and 24.