6–VMware Driver Software
FCoE Support
54
83840-546-00 D
or to persist the settings across reboots with the command
esxcfg-module -s multi_mode=0 bnx2x
Reboot the machine for the settings to take place.
MultiQueue/NetQueue
The optional parameter
num_queues
may be used to set the number of Rx and
Tx queues when
multi_mode
is set to 1 and interrupt mode is MSI-X. If interrupt
mode is different than MSI-X (see
int_mode
parameter), the number of Rx and Tx
queues will be set to 1, discarding the value of this parameter.
If you would like the use of more then 1 queue, force the number of NetQueues to
use with the following command:
esxcfg-module -s "multi_mode=1 num_queues=<num of queues>" bnx2x
Otherwise, allow the bnx2x driver to select the number of NetQueues to use with
the following command:
esxcfg-module -s "multi_mode=1 num_queues=0" bnx2x
The optimal number is to have the number of NetQueues match the number of
CPUs on the machine.
FCoE Support
This section describes the contents and procedures associated with installation of
the VMware software package for supporting QLogic FCoE C-NICs.
Enabling FCoE
To enable FCoE hardware offload on the C-NIC
1.
Determine the ports that are FCoE-capable:
# esxcli fcoe nic list
Output example:
vmnic4
User Priority: 3
Source MAC: FF:FF:FF:FF:FF:FF
Active: false
Priority Settable: false
Source MAC Settable: false
VLAN Range Settable: false
Summary of Contents for 8400 Series
Page 390: ......