END OF SEASON OPERATIONS
To empty the internal circuit completely of water, remove the cap(fig. 32).
Run off all water left into a basin. When all the water has been drained, put the
cap back in place. Clean the filter and dry thoroughly before putting back.
L
TROUBLE SHOOTING
Phenomenon
Troubleshooting
Solution
The appliance does
not come on
• There is no current
• It is not plugged into the
mains
• The internal safety device has
tripped
•Wait
• Plug into the mains
• Wait 30 minutes, if the problem
persists, contact your service center
The appliance works
for a short time only
• Here are bends in the air
exhaust hose
• Something is preventing the
air from being dis charged
• Position the air exhaust hose
correctly, keeping it as short and
free of curves as possible to avoid
bottlenecks
• Check and remove any obsta-cles
obstructing air discharge
The appliance works,
but does not cool the
room
• Windows, doors and/or
curtains open
• Close doors, windows and curtains,
bearing in mind the “tips for
correct use” given above
• There are heat sources in the
room (oven, hairdryer, ate)
• Eliminate the heat sources
• The air exhaust hose is
detached from the appliance
• Fit the air exhaust hose in the
housing at the back of the
appliance
• The technical specification of
the appliance is not adequate
for the room in which it is
located
During operation,
there is an unpleasant
smell in the room
• Air filter clogged
• Clean the filter as described there is
an above
The appliance does
not operate for about
three minutes after
restarting it
• The internal compressor safety
device prevents the appliance
from being restarted until
three minutes
• Wait. This delay is part of normal
operation
The following
message appears on
the display:
• The appliance has a self
diagnosis system to identify a
number of malfunctions
• See the SELF-DIAGNOSIS Chapter
Never attempt to disassemble or repair the device. Inexpert repairs invalidate the
guarantee and can endanger the users of the device.
M
GUARANTEE CONDITIONS
The air conditioner is supplied with a 24-month guarantee, commencing on the
date of purchase. All material and manufacturing defects will be repaired or
replaced free of charge within this period. The following rules apply:
1. We expressly refuse all further damage claims, including claims for collateral
damage.
2. Repairs to or replacement of components within the guarantee period will
not result in an extension of the guarantee.
Fig. 32
4
82