2
3
Zone
definitions(Gas)
Zone 1
High risk gas/vapour
Zone 2
Medium risk gas/vapour
Group
definitions(Gas)
GROUP
II A
Acetone, Petrol, Methanol, Propane, Toluene
GROUP
II B
Ethylene, City gas
GROUP
II C
Hydrogen, Acetylene, Carbon sulphide
Maximum surface
temperature of
electrical equipment
T1
450°C
T2
300°C
T3
200°C
T4
135°C
T5
100°C
T6
85°C
Zone
definitions(Dust)
Zone 21
High risk powder/dust
Zone 22
Medium risk powder/dust
Group
definitions(Dust)
GROUP
III A
Ignitible fibers/flyings(more than 0.5mm)
GROUP
III B
Non-conductive dusts
GROUP
III C
Conductive dusts
QLEX-TRI
-
240(PL)
-
24
[Model number]
[Length]
[Voltage]
|
|
|
• QLEX-TRI
• 240-240mm
• 24-DC24V
General Product Specification
Model number
QLEX-TRI-240(PL)
Rated voltage
DC24V
Range for operation
voltage
DC21.5V-26.5V
Power consumption
8.6W
Insulation resistance
Min. 100MΩ(500V DC mega ohm meter)
Withstanding voltage
DC : 500VAC, 60Hz, 1 minute
Protection rating
IP66/67
Materials
Side cover-Al, Lens-PC, Bracket-PC
Certificate
Weight(approx.)
0.62Kg
Optics Specifications
Model number
QLEX-TRI-240(PL)
Lens color
Translucent
Light color (Standard)
Cooldaylight
Color temperature
(Standard)
6,000-7,000 K
Luminous flux
650lm
Illumination(at 1m)
310Lux
Model number
QLEX-TRI-240(PL)
Range for
operating voltage DC24V
Ex mark
Ex d IIC T6
Ambient operating
temperature
–40°C ≤ Tamb ≤ +60°C
Explosion proof
Group / Zone
Zone1, Zone2
Protection rating
IP66/ IP67
■
Explosion Proof Specifications
Product Specifications
Ordering Specifications
■
Optics Specifications/ General Product Specification
Summary of Contents for QLEX-TRI-240
Page 6: ...MEMO...
Page 7: ...MEMO...