• Connect RJ45 connector that is connected to UTP cable to 

  Ethernet port of a PC or a router.

• External power line - UL1015 AWG18(0.75sq) x 2C 400mm 

• For AC type, power cable is equipped with the product.

• UTP Cable : Category 5 cable

DC/ AC

Power

Fuse

White

Black

RJ45

Wiring Instructions

5. When you unzip “ETN TEST PROGRAM.zip” file, following folders are created.

4. When you unzip the file, there will be a file with the same name below. The instructions are listed inside the file.

Program Sample needed when developing

(x32bit/x64bit compatibility)

Instructions of how to use the product and library file

A program for setting IP before testing the ETN device

A program for setting testing the ETN device

PC

RJ45

HUB

EtherNet Tower

VDC 12/24

EtherNet Network

VAC 110V-220V

■ Test Ethernet LED Tower Light

1. Please connect LAN cable of the tower light to the router so that 

    the tower light can access Ethernet network by referring left 

    diagram.

2. Please be sure that the power supply shall meet the product 

    specification accordingly.

Product Installation

Installation wiring instructions

2. Because the ETN tower light is connected to a hub with the PC that is same as the picture on the front page, ETN tower

 

    light and the PC are now connected with the same network.
3. Please download the product manual, library file and test program from Qlight website(www.qlight.com) or blog.qlight.com

1. Please activate default PC network only. Please run Windows CMD(Command line) of PC over the same network in order to confirm
    network information where the Ethernet product will be connected.
    Example) Windows 7 : Start(Run)->CMD->ipconfig /all
                    Windows 10 : Start menu-> Click right mouse button->CMD->ipconfig /all
   - Please refer to below network information when the Ethernet product’s network environment is configured.

Applying the Ethernet Device

Ethernet adapter 

Local Area Connection

:

Connection-specific DNS Suffix  . :
IP Address. . . . . . . . . . . . : 192.168.10.101
Subnet Mask . . . . . . . . . . . : 255.255.255.0
Default Gateway . . . . . . . . . : 192.168.10.1

Summary of Contents for ST45L-ETN-BZ

Page 1: ...ngs indicated for each product Failure to follow these instructions may cause a fire to the product electric shock physical injury malfunction or damage to the product 3 Do not alter or repair this pr...

Page 2: ...mber G Green B Blue W White ST56 M EL ETN Model number Layer Voltage Current Certificate Color ST56EL ETN ST56MEL ETN 1 DC12V DC24V AC110V 220V 0 215A 0 150A Max 0 060A R Red 2 DC12V DC24V AC110V 220V...

Page 3: ...AYER 1 2 3 4 5 L 257 322 387 452 517 56 10 40 L 207 PCD 40 360 3 M4 BOLT 8 CABLE ENTRY RJ45 LAN CONNECTOR POWER CABLE 56 18 10 40 L 195 26 200 RJ45 LAN CONNECTOR POWER CABLE M18 1 5 THREAD M18 1 5 THR...

Page 4: ...access Ethernet network by referring left diagram 2 Please be sure that the power supply shall meet the product specification accordingly Product Installation Installation wiring instructions 2 Becau...

Page 5: ...nformation identified in the previous chapter subnet mask gateway in each text box and set a different IP_Addr than your PC Apply the settings by pressing the Write button The port is set to 20000 by...

Page 6: ...it Caution when lens kit Lens kits are connected with connector pins each other Bad connec tion may be experienced when the connector pins are touched with a foreign substance If the lens kits are not...

Page 7: ...T80MEL ETN Direct Mounting Type Model Installation Environment and Protection Rating This product is designed for use with protection rating of IP23 If the product is installed in locations that subje...

Page 8: ...5 HOLES PCD 56 60 57 4 5 5 HOLES 19 CABLE ENTRY 18 90 PCD 73 4 5 5 HOLES 2 8 5 HOLES PCD 54 56 90 18 4 6 HOLES 45 5 66 11 CABLE ENTRY PCD 73 18 70 51 5 67 4 5 5 HOLES 18 CABLE ENTRY PCD 54 56 Dimensi...

Page 9: ...81 32 34 46 M24x1 5 THREAD 2 8 5 HOLES 69 5 52 38 34 46 50 70 1 2 PF 4 5 HOLES 12x22 CABLE ENTRY 33 24 70 55 4 5 5 HOLES PCD 54 56 24 4 5 HOLES 90 55 5 PCD 73 24 35 24 24 60 57 90 19 CABLE ENTRY PCD...

Page 10: ...Laboratories Qlight s design and quality assurance system has been certified from UL to ensure the stability of consumption goods and to protect consumers CCC CCCF Security Protection Qlight s has ob...

Page 11: ...MEMO...

Page 12: ...hina Tel 86 21 6651 7100 Fax 86 21 6315 3929 China Factory Site 2 Qidong 33 Haiyan Road Qidong High tech Industrial Development Zone Qidong Jiangsu Province China Tel 86 513 8384 9999 Fax 86 513 8384...

Reviews: