2

Model number

SNE-TI
SNEL-TI
SNELR-TI
SNE-S-TI

Range of 

operating voltage

DC 12V or 24V

AC 120V or 230V

Ex mark

IECEX - Ex db IIC T6 Gb, Ex 

db op is IIC T6 Gb

ATEX – 

 II2G Ex db IIC T6 

Gb, Ex db op is IIC T6 Gb

Ambient 

operating 

temperature

–40°C ≤ Ta ≤ 60°C 

Explosion proof 

Zone

Zone1, Zone2

Protection rating IP66

Model

number

Voltage

Power 

consumption

Current

Bulb specifications

Certificate

Weight

Color

Volts/Watts

Configuration

Part#

SNE-TI

DC12V

25.3W

1.430A

12V15W

G23 15S

17

3.60kg

R-Red

A-Amber

G-Green

B-Blue

DC24V

0.720A

24V15W

G23 15S

18

AC120V

0.180A

12V15W

G23 15S

17

4.25kg

AC230V

0.110A

12V15W

G23 15S

17

SNE-S-TI

DC12V

18.4W

0.430A

220V

-350V

BGA2120

-BBC

I type

47

3.25kg

DC24V

0.230A

AC120V

0.120A

3.95kg

AC230V

0.080A

Model

number

Voltage

Power 

consumption

Current       

Certificate

Weight

Color

SNEL-TI

DC12V

9.2W

0.130A

3.15kg

R-Red

A-Amber

G-Green

B-Blue

DC24V

0.120A

AC120V

0.050A

3.85kg

AC230V

0.040A

SNELR-TI

DC12V

9.2W

0.210A

3.65kg

DC24V

0.150A

AC120V

0.050A

4.30kg

AC230V

0.040A

Product Specifications

Ordering Specifications

■ 

Explosion Proof Specifications

■ 

General Product Specifications

Zone 

definitions(Gas)

Zone 1

High risk gas/vapour(Gas)

Zone 2

Medium risk gas/vapour(Gas)

Group 

definitions(Gas)

GROUP 

II A Acetone, Petrol, Methanol, Propane, Toluene

GROUP 

II B Ethylene, City gas

GROUP 

II C Hydrogen, Acetylene, Carbon sulphide

Maximum surface 

temperature of 

electrical Equipment

T1

450°C

T2

300°C

T3

200°C

Zone 

definitions(Dust)

T4

135°C

T5

100°C

Group 

definitions(Dust)

T6

85°C

Zone 21

High risk powder/dust(Dust)

Zone 22

Medium risk powder/dust(Dust)

Group

definitions(Dust)

GROUP 

II A

Ignitible fibers/flyings(more than 0.5mm)

GROUP 

II B

Non-conductive dusts

GROUP 

II C Conductive dusts

Telephone lines rated power

• 

Rated power when telephone lines are not in use: 45VDC - 55VDC

• 

Rated power when telephone rings : 95VDC - 130VDC(Ring Ring signal sound)

SNE

-

230

-

R

-

TI

[Model number]

[Voltage]

[Color]

[Telephone Initiated]

|

|

|

|

• 

SNE

• 

SNEL

• SNELR

• SNE-S

• 12-DC12V

• 24-DC24V

• 120-AC120V

• 230-AC230V

R-Red

A-Amber

G-Green

B-Blue

TI-

Telephone Initiated

Summary of Contents for SNE-TI

Page 1: ...emperature rating 5 Before installing the product please make sure all cautions indicated on the labels packaging and operation manual of the product are fully understood 6 Installation maintenance an...

Page 2: ...LR TI DC12V 9 2W 0 210A 3 65kg DC24V 0 150A AC120V 0 050A 4 30kg AC230V 0 040A Product Specifications Ordering Specifications Explosion Proof Specifications General Product Specifications Zone definit...

Page 3: ...s insert the bolt through the hole of the product and tighten the nut from the opposite side of the mounting surface Installation Housing Al Terminal cover Al Protection cage STS316L Lens Tempered gla...

Page 4: ...U type or ring O type locking spade terminal at naked tip of the wire for secure connection Connect the power line to the terminal and Connect the telephone signal cable to the terminal and For AC ty...

Page 5: ...website www qlight com Bulb Replacement Instructions Xenon Bulb Replacement lnstructions Xenon Bulb Replacement Instructions SNE S only Please wait at least 30 mimutes after turning off the power befo...

Page 6: ...ing the sky Sounder part shall not be facing the sky BEACON SIGNALING LIGHT Power cord inlet part shall not be facing the sky Power cord inlet part shall not be facing the sky SIGNAL TOWER LIGHTS HEAV...

Page 7: ...MEMO...

Page 8: ...China Tel 86 21 6651 7100 Fax 86 21 6315 3929 China Factory Site 2 Qidong 33 Haiyan Road Qidong High tech Industrial Development Zone Qidong Jiangsu Province China Tel 86 513 8384 9999 Fax 86 513 838...

Reviews: