19
Installation And Operation Manual
For
DTPO610VC
●
Make sure that tool trays, stands or persons are removed or evacuated from under vehicle.
●
Lower vehicle by activating lowering handle.
●
Before removing vehicle from lift area, position the lift arms and the supports to provide
an
unobstructed exit.
●
NEVER, drive over lift arms.
REQUIRED MONTHLY UPKEEP
●
Check arm restrains for proper operation.
●
Check all chain/cable connections, bolts and pins to ensure proper mounting.
●
Visually inspect safeties for proper operation.
●
Lubricate columns with grease.
●
Inspect all anchor bolts and retighten if necessary.
●
Check columns for squareness and erectness.
●
Inspect all arm pivot pins to make sure that they are all properly secured.
●
Check the tensions of equalizer cables, adjust if necessary.
●
Inspect all lift pads, replace if necessary.
●
If lift is equipped with overhead cut-off switch, check for proper operation.
WARNING
1.
If cement anchor bolts are loose, or any component of the lift is found to be defective, DO NOT USE
LIFT.
2.
Never operate the lift with any person or equipment below.
3.
Never exceed rated capacity.
4.
Always ensure that safeties are engaged before any attempt to work on or near the lift.
5.
Never leave lift in an elevated position unless the safeties are engaged.
6.
Do not permit electric motor to be damp! Motor damage caused by dampness is not covered under
the warranty.
NEVER LIFT ANY VEHICLE IN ANY MANNER WITH LESS THAN FOUR (4) ARMS.
RATED CAPACITY OF EACH LIFT ARM IS NOT GREATER THAN ONE FOURTH (1/4)
OF THE OVERALL LIFTING CAPACITY.