SQ Remote Power Management User’s Manual
5.4 Power Outlet Timer Setup Menu:
Figure18 show the power outlet entry table. This is an example of the power outlet in
Timer off mode. To enable the Timer, select “Timer Mode” on.
Figure 20 - Power Outlet Timer Setup Menu (Web Page)
•
Timer Mode:
Select the timer mode: Off/Standard/Customized
•
Timer Start Time:
Specify starting time for the timer. The starting time is the actual calendar date and real-time
clock. Once a timer reaches this specified Start Time, the power outlet on/off state will flip. It
is in the format of “year:month:day:hour:minute:second”. For example, to start changing the
power outlet on/off state at 7:17:27pm, on July 20
th 2008
, the entry data is 08:07:20:19:17:27.
•
Timer Period:
Specify the timer period. It is in the format of “days:hours:minutes:seconds”, which is not a
calendar and real-time clock entry type. The period setting is used for applications that
require the power outlet to continuously change on/off in a specific interval. For example, you
need to schedule power reboot for the outlet daily, the period is 24 hours. Your entry will be
00:24:00:00.
•
Timer Loop Count:
The number of Periods for the Timer is defined as Loop Count. For example, you schedule
the timer to flip the power outlet states in every 20 seconds and want to repeat 300 times,
your entry will be 300.
____________________________________________________________
25
Addr
:
A/4F, 2# Building , No.401, Caobao Road , Shanghai ,China Zip
:
200233 Web
:
www.sq-catv.com
Fax
:
86-21-64858301 - 62401979 Tel
:
86-21-54973555 – 34140103 - 64957666 E-mail
: