Before Start: Install "All-In-One" Pack

All-In-One Pack  Driver, SDK and Software) for WINDOWS supports all QHYCCD USB3.0 devices only except PoleMaster
and some discontinued CCD cameras. Please go to 

https://www.qhyccd.com/download/

 and install it.

Note:

Since most of the contents of All-in-one package are plug-ins that support third-party software,  the third-party
capturing software that you want to use must be installed before the All-in-one package.
 Otherwise the program
will report an error.
ALL-IN-ONE Pack contains:

System Driver, which is necessary for camera operation and must be installed.
WDM Broadcast Driver, which can provide a live signal to Obs and other live software, you can install it if you
have such needs like opeing a live show.
EZCAP_QT , which is developed by QHYCCD and can be used in QHY devices tests, and management of
updates. So even if you won’t use EZCAP_QT for capturing, we suggest you install it.
Ascom driver needs to be sync with the ascom platform version you installed (the latest version of Ascom is
6.5)
The two sorts of Ascom CFW Drivers correspond to two methods of controling the filter wheel: USB control
and camera serial control. It is recommended that both drivers should be installed if you have a filter wheel.
CP210X_VCP is a serial driver. Some computers come with the driver, but the computer without the driver
may be failed of controling the filter wheel.
SDKs for Third-party Software: Just pick and install the corresponding SDK according to the software you
want to use. Don’t forget to check whether the software you are using is 32-bit or 64-bit and select the right
SDKs.
SHARPCAP is also included in the pack, you can choose 32-bit or 64-bit to install. This is authorized by
SHARPCAP.
QT LIB is a plug-in to ensure that 64-bit software can exeuate normally on some computers with poor
compatibility.

Difference between Stable version and Beta Version: Beta version is the latest version, which gives priority to
support for the latest products (the stable version may not be compatible with those yet), and has some of the latest
optimized ,but experimental features. The stable version is older than the beta version but more stable, so it is
recommended for beginners who are not using the latest products.
Don’t let the camera connect to the computer during the All-in-one pack installation process;  connect it to the
computer after all the installation is complete.

 

 

 

Input Voltage Requirements

The camera requires an input voltage between 11V and 13.8V. If the input voltage is too low the camera will stop
functioning or it may reboot when the TEC power percent is high, causing a drain on the power. Therefore, please make
sure the input voltage arrived to the camera is adequate. 12V is the best but please note that a 12V cable that is very long or
a cable with small conductor wire may exhibit enough resistance to cause a voltage drop between the power supply and
the camera. The formular is: V(drop) = I * R (cable). It is advised that a very long 12V power cable not be used. It is better to
place the 12V AC adapter closer to the camera.

First connect the 12V power supply, then connect the camera to your computer via the USB3.0 cable. Make sure the
camera is plugged in before connecting the camera to the computer, otherwise the camera will not be recognized. When
you connect the camera for the first time, the system discovers the new device and looks for drivers for it.  You can skip the
online search step by clicking “Skip obtaining the driver software from Windows Update” and the computer will
automatically find the driver locally and install it. If we take the 5IIISeries driver as an example (shown below), after the
driver software is successfully installed, you will see QHY5IIISeries_IO in the device manager.

Please note that the input voltage cannot be lower than 11.5v, otherwise the device will be unable to work normally.

Connect Software

Before using software, make sure you have connected the cooling camera to the 12V power supply and connected it to the
computer with a USB3.0 data cable. If it’s a planetary/guiding camera, 12V power is not needed.

Note: We recommend 64-bit Software if possible, like SharpCAP x64 , N.I.N.A x64. etc., especially when you’re using 16bit
cameras like QHY600.

EZCAP_QT

Summary of Contents for QHY990

Page 1: ...GaAs sensor has a high dark current than Silicon based material If you are doing the long exposure with this camera eg exposure 5 sec QHYCCD recommends selecting the liquid cooling version Applications SWIR Astronomy Imaging and Photometry Daytime Star Observing Optical Communication Laser Optic Labs Specifications Model QHY990 QHY991 CMOS Sensor IMX990 SWIR Sensor IMX991 SWIR Sensor FPA Material ...

Page 2: ... Trig In Socket RCA type Opto isolated Computer Interface USB3 0 Lens Interface C Mount Telescope Interface 1 25inch Adapter Basic Interface Flange with 6 M3 screw holes 25mm Filter Adapter Support D 25mm and D 25 4mm filter Back Focal Length C_Mount 1 25inch adapter 17 5mm with 25mm filter adapter 14 5mm without filter adapter Basic Interface 12 5mm Cooling System Dual Stage TE Cooler Air Cooling...

Page 3: ......

Page 4: ...Mechanical Dimentions ...

Page 5: ......

Page 6: ...lens F2 8 1200 1800nm filter Gain 0 exposure time 1 3ms D0wnload 16bit FITs QHY990_DAYTIMEQHY990_DAYTIME QHY990 Sample image under sky at night With 16mmF1 4 SWIR lens F1 4 1200 1800nm filter Exposure 2sec stack 29frames 11C sensor temperature Dark frame calibrated ...

Page 7: ...Here are the stars in the daytime with QHY991 camera by Martin Miller ...

Page 8: ...Brief User Guide ...

Page 9: ...atible with those yet and has some of the latest optimized but experimental features The stable version is older than the beta version but more stable so it is recommended for beginners who are not using the latest products Don t let the camera connect to the computer during the All in one pack installation process connect it to the computer after all the installation is complete Input Voltage Req...

Page 10: ... to 10C The temperature of the CMOS sensor will drop quickly to this temperature approximately 2 3 minutes If you want to turn off cooling you can choose Stop If you just want to set the TEC power but not the temperature You can select Manual and then set the percentage of the TEC power You can use the preview tab to preview and use the focus tool to focus Then use the capture tab to capture the i...

Page 11: ... temperature control circuit will be activated You can control the CMOS temperature by adjusting the settings in the figure below Basically you can control the temperature of CMOS by either adjusting Cooler Power or clicking Auto and setting Target Temperature You can also see the CMOS temperature at the lower left corner of the software window ASCOM supported software e g MDL With ASCOM drivers y...

Page 12: ...N I N A Open N I N A Nighttime Imaging N Astronomy Drive connections via ASCOM ...

Page 13: ...that supports QHYCCD cameras with video broadcast function which can meet the needs of customers to send video images to other target software For example use sharpcap to connect a WDM enabled camera and the sharpcap display video image can be sent to other WDM supported software for display which is suitable for video online broadcast applications Installation Perform the AllInOne installation an...

Page 14: ...k that the image device name is QHYCCD BroadCast WDM Camera which means the installation is successful Activate the function Usually sharpcap is used to connect the camera as the broadcasting terminal After connecting the camera you need to turn on the Enable Live Broadcast switch to broadcast ...

Page 15: ...Common supporting software ie broadcast receiver includes UFOCAPTURE HANDYAVI QQ video functions etc AMcap test effect chart HANDYAVI test effect chart ...

Page 16: ...test renderings Precautions Currently only supports Windows system Currently the SDK does not support 16 bits for the time being RGB24 mode must be selected for color images otherwise the image will appear gridded ...