background image

 

Caracteristici

 

1) 

Fereastra emisie Laser

  2) 

Pornit

/

Oprit

-

Comutator rotativ

  3) 

LED control pornit/oprit

  4) 

Cerc 

360° 

ajustabil

  5) 5/8“-

conector pe trepied

  6) 

Compartimentul bateriilor

EL 601

  Features

  1) Laser emitting window
  2) On/Off switch
  3) Power LEd
  4)  adjustable 360° circle
  5) 5/8“-11 screw thread
  6) Battery compartment

www.

geo-fennel-echipamente.ro

2

 

Setul contine:

 

Nivela laser in cruce,trepied cu coloana reg-

 

labila, ochelari, cutie transport pentru toate 

  Supplied with

  Cross laser, elevating tripod, laser glasses, 
  hard case, batteries, users‘ manual

   

       Date Tehnice:

precizia

 

+/- 4 mm / 10 m

Interval autonivelare

+/- 5°

Zona de lucru 

 O: 

 

20 m*

Lungime de unda laser

 

635nm

Sursa de alimentare

  3 x aaa   

 

 

 

Bateri

i

Interval Temperatura

:   

0 - 40°C

Clasa Laser: 

 

2m

Durata viata baterie

 

12 h

 

  *

depinde de intensitatea luminii din camera







    Technical data

accuracy: 

 

+/- 4 mm / 10 m

Self levelling range:   

+/- 5°

Working range O: 

 

20 m*

Wave length: 

 

635nm

Power supply: 

 

3 x aaa   

 

 

 

batteries

Temperature range:   

0 - 40°C

Laser class: 

 

2m

Betriebsdauer: 

 

12 h

 

  *depending on room illumination







1

4

5

3

2

6

componentele, baterii, Manual de Utilizare.

Summary of Contents for EL 601

Page 1: ...SET Selbstnivellierender Kreuzlaser SET Self Levelling Cross Laser BEdiEnungSanLEiTung EL 601 uSErS manuaL T ools not toys Scule nu Jucarii MANUAL UTILIZARE SET Nivela laser autonivelanta cruce laser ...

Page 2: ...ort pentru toate Supplied with Cross laser elevating tripod laser glasses hard case batteries users manual Date Tehnice precizia 4 mm 10 m Interval autonivelare 5 Zona de lucru O 20 m Lungime de unda laser 635nm Sursa de alimentare 3 x aaa Baterii Interval Temperatura 0 40 C Clasa Laser 2m Durata viata baterie 12 h depinde de intensitatea luminii din camera T echnical data accuracy 4 mm 10 m Self ...

Page 3: ...trebuie sa fie mai mare de 2 mm a1 a2 si b1 b2 T esting accuracy of line sight Set up instrument in the middle of two walls which are about 5 m apart mark a visible laser cross on the wall Turn unit to opposite wall and mark laser cross repeat measurements with distance of 0 6 m to one wall and about 4 4 m to second wall deviation between two measurements taken from the centre and two measurements...

Page 4: ...sa coincida cu pozitia firului cu plumb Toleranta este de maxim intre ele 2 0 mm T esting accuracy of vertical line end to end Set up instrument about 5 m from a wall Fix a plumb line of 2 5 m length to the wall using a plumb bob Bring vertical line into coincidence with the plumb line deviation between laser line and plummet cord from top to bottom must not exceed 2 0 mm Caracteristici 1 Laser in...

Page 5: ...ctiuni de siguranta Nu lasti la indemana copiilor umgebung betreiben Instructiuni Siguranta intended use of instrument The instrument emits a visible laser beam in order to carry out the following measuring tasks depending on instrument Setting up heights horizontal and vertical planes right angles and plumbing points Safety instructions Safety instructions Please follow up instructions given in o...

Page 6: ...ment Motivele specifice pentru mãsurarea rezultatelor eronate Mãsurãtorile prin ferestre din sticlã sau din material plastic Fereastra emisiei laserului murdara Dupã ce instrumentul a fost scãpat pe jos sau lovit Vã rugãm sã verificaþi acurateþea Largi fluctuatii de temperatura daca nivela va fi utilizat in zone reci dupa ce a fost depozitat in zone calde si invers aceasta trebuie lasata cateva mi...

Page 7: ...ta sau folosita abuziv Garantia nu se aplica in cazul curgerii bateriei depozitarii in spatii cu temperatura foarte mica sau mare Garantia nu se aplica si bateriei Electromagnetic acceptability EmC it cannot be completely excluded that this instrument will disturb other instruments e g navigation systems will be disturbed by other instruments e g intensive electromagnetic radiation nearby industri...

Page 8: ... daune cauzate de miþcarea greþite sau de acþiune din cauza conectarii cu alte aparate Exceptions from responsibility The user of this product is expected to follow the instructions given in operators manual although all instruments left our warehouse in perfect condition and adjustment the user is expected to carry out periodic checks of the product s accuracy and general performance The manufact...

Reviews: