A
BOUT
YOUR
S
YSTEM
I
NTRODUCTION
1-3
Power supply
1+1 High efficiency redundant hot-plug 700W PSU (default with one PSU
only);
100-240Vac, 50-60Hz, 10-5A;
100-240Vac, 50-60Hz, 10-5A or 240Vdc, 3.5A (for China only);
Detailed PSU options please refer to “ordering info” or “CCL”
Rating (per PSU inlet)
100-240Vac, 10-5A, 50/60Hz
Fan
6x systems fans
System management
IPMI v2.0 Compliant, on board "KVM over IP" support
Operating environment
Operating temperature: 10°C to 40°C (50°F to 104°F)
Non-operating temperature: -40°C to 70°C (-40°F to 158°F)
Operating relative humidity: 50% to 90%RH
Non-operating relative humidity: 20% to 95%RH
Table 1.1: System Specifications (Continued)