background image

2

3

INSTaLLaTIoN aND oPeraTIoN MaNUaL SoLar MoDULeS GeNeraTIoN 3 (G3) – HaNwHa Q CeLLS GMBH – Na

INSTaLLaTIoN aND oPeraTIoN MaNUaL SoLar MoDULeS GeNeraTIoN 3 (G3) – HaNwHa Q CeLLS GMBH – Na

Document Revision 03
This Installation Manual is valid for USA and Canada as of January 2015 for Q.PRO-G3, Q.PRO BFR-G3, Q.PEAK-G3, Q.PEAK BLK-G3 and Q.PLUS-G3 solar modules, and replaces 
all earlier versions. 

Technical parameters and the design are subject to change. The data sheets and customer information valid at the point in time when the relevant module was manufactured apply 
to the installation, mounting, and maintenance procedures for the respective solar modules. 

with solar modules from Hanwha Q CeLLS GmbH (hereafter referred to 
as "Q CeLLS") you can directly transform the sun’s limitless energy into 
environmentally-friendly solar electricity.

In order to ensure the maximum performance of your Q CeLLS solar 
modules, please read the following instructions completely and care-
fully and observe all guidelines. Non-compliance may result in damage 
and/or physical injury.

This installation manual provides instructions for the safe installa-
tion of crystalline solar modules.

 

Ä

Please read these instructions carefully before proceeding with 
your installation.

 

Ä

Please retain these instructions for the life of the solar modules.

 

Ä

Please ensure that this installation manual is available to the 
operator at all times.

 

Ä

This installation manual should be given to all subsequent owners 
or users of the solar modules.

 

Ä

All supplements received from the manufacturer should be 
included.

 

Ä

Please observe all other applicable documents.

Intended Use

This manual is valid in North America for Q CELLS solar modules. 
These instructions contain information regarding the safe handling 
and use of quality crystalline solar modules from Q CELLS and for 
their installation, mounting, wiring, and maintenance. 

Symbols and Labels

The following symbols and labels are used throughout the 
installation manual for ease of use. 

SyMBoL

DeSCrIPTIoN

 

Ä

 

Procedure with one or more steps. 

• 

 

Lists of items

Ensure that when carrying out a pro-
cedure, you check the results of said 
procedure.
  

Prohibited.
 

Beware of possible danger or damage. 
Categories:

• 

Danger: Risk of fatal injury

• 

Attention: Risk of serious injury 
or damage to property

• 

Note: Risk of damage to product

Units

Where both metric and U.S. units (for example inches) are shown, 

metric units are definitive. References to “Data Sheet” or “Module 
Data Sheet” refer to the Module Data Sheet applicable to the module 

being used.

Safety regulations

The installer and solar module operator are responsible for 
compliance with all applicable statutory requirements and 
regulations. 

 

Ä

The following regulations and standards must be upheld at all 
times during the installation, operation, and maintenance of the 
solar modules: 

• 

Installation and Operation Manual.

• 

Other applicable documents (such as country-specific regulations 

for pressure equipment, operational safety, hazardous goods, 
and environmental protection).

• 

Regulations and requirements specific to the system.

• 

Applicable country-specific laws, regulations, and provisions 

governing the planning, installation, and operation of solar 
power systems and work on roofs.

• 

Valid international, national, and regional regulations governing 
work with direct current, especially those applicable to the 
installation of electrical devices and systems, and regulations 
issued by the respective energy provider governing the parallel 
operation of solar power systems.

• 

Accident-prevention regulations.

Certified Personnel

Both, the operator and installer are  responsible for ensuring that 
installation, maintenance, connection to the grid, and dismantling 

are carried out by trained and qualified electricians and engineers 
with  approved  training  certificates  (issued  by  a  state  or  federal 

organization) for the respective specialist trade.

Electrical  work  may  only  be  performed  by  an  officially  certified 

tradesperson in accordance with the applicable safety standards, 
accident prevention regulations, and the regulations of the local 
energy provider.  

TaBLe oF CoNTeNTS

1  INTroDUCTIoN  

3

2 PLaNNING  

5

2.1  Technical specifications 

 

5

2.2 requirements 

 

7

2.3  Mounting options  

8

2.4  electrical layout  

10

3 INSTaLLaTIoN 

 

11

3.1  Safety and transport  

11

3.2  Preparation of installation  

13

3.3  Module installation  

14

4  eLeCTrICaL CoNNeCTIoN  

15

4.1 Safety 

 

15

4.2  electrical installation safety  

16

4.3  Connection of modules  

17

4.4  after installation  

18

5 GroUNDING 

 

19

6  FaULTS aND DeFeCTS  

19

7 DISPoSaL 

 

19 

8  MaINTeNaNCe aND CLeaNING  

20

1 INTroDUCTIoN

Summary of Contents for Q.Pro-G3

Page 1: ...Valid for North America Q Pro G3 Q Pro BFR G3 Q Peak G3 Q Peak BLK G3 Q PLUS G3 Installation and Operation Manual...

Page 2: ...amage Categories Danger Risk of fatal injury Attention Risk of serious injury or damage to property Note Risk of damage to product Units Where both metric and U S units for example inches are shown me...

Page 3: ...complete solar power system It may be necessary to carry out a structural analysis for the entire project If your questions are not satisfactorily answered in the manual please contact your system sup...

Page 4: ...ufficient rear ventilation of the module Guarantees long term stability Has electrochemical series that prevent corrosion among different metals Allows for stress free expansion and contraction due to...

Page 5: ...0 380 CL1 9 65 17 52 245 445 7 09 14 96 180 380 2 Planning 2 3 Mounting options Specifications Module type Mounting option Clamping range1 IN Mm Allowed static load2 PA TEST LOAD acc IEC 61215 PA Q PR...

Page 6: ...termining the maximum number of modules in the string Parallel Connection Modules may be damaged by the occurrence of reverse currents caused by module defects ground leaks or defective insulation Ens...

Page 7: ...ng until installation Store the modules securely in cool and dry rooms The packaging is not weatherproof Danger Risk of fatal injury due to electric shock Do not install damaged modules Inform your ve...

Page 8: ...to electric shock Only use dry insulated tools Do not carry out the installation alone Only install undamaged modules and components Do not drill any other holes 3 2 Preparation of installation 3 Inst...

Page 9: ...wiring with extreme caution Ensure that the modules are disconnected at the inverter prior to separation Be sure to observe the specified time intervals after switching off the inverter High voltage c...

Page 10: ...ock Ensure that all electrical components are in a proper dry and safe condition A module with 47 24in long 1 210 mm cable can be wired as a 2nd next neighbor 2nd next neighbor Wiring without a return...

Page 11: ...rformance Maintenance The system should be inspected by an installer annually to check the following all system components sit securely and are corrosion free the connection is secure and all electric...

Page 12: ...vine Center Drive Suite 1250 Irvine CA 92618 USA TEL 1 848 748 59 96 FAX 1 949 748 59 84 EMAIL q cells usa q cells com WEB www q cells us Subject to change without notice Hanwha Q CELLS GmbH Installat...

Reviews: