QBD Cooling Systems Inc. AC48 Safety, Installation And Instructions Download Page 22

  

 

               QBD COOLING SYSTEMS INC.

 

 

 

20 

08 -2015 

 

                                                                              47-0480-192-N 

Compressor starts, 

but does not switch 

off from start winding 

 

Improper wiring 

 

Low voltage 

 

Relay failed 

 

Run capacitor failed 

 

Excessive high discharge 

temperature 

 

Compressor failed 

 

Wrong setting of LP/HP switch 

 

Check wiring against diagram 

 

Find out the reason & correct 

 

Replace relay 

 

Replace capacitor 

 

Check for over charge or condenser 

blockage / condenser fan failure 

 

Replace compressor 

 

Reset the LP/HP switch to correct 

setting 

Compressor starts 

and runs, 

but short cycles on 

the 

overload protector 

 

Excess current passing through 

overload 

 

Low / unstable voltage 

 

Overload failed 

 

Capacitor fault 

 

Excessive discharge 

 

Suction pressure too high 

 

Compressor overheating 

 

Compressor electrical fault  

 Check wiring diagram for wrong connections 

of electrical components 

 Find out the reason & correct 

 Replace overload 

 Replace capacitor 

 Check for over charge or condenser 

blockage / condenser fan failure  

 Check refrigerant charge 

 Replace compressor 

Units runs OK, But 

short   cycles  

 Overload protection 

 Thermostat 

 Check the wiring  

 Replace the overload 

 Change the thermostat setting if required 

Warm temperature 

 Control setting at warm 

 Inadequate air circulation  

 Reset the controller setting to colder 

 Improve air movement  

Summary of Contents for AC48

Page 1: ...io Canada L6W 3K6 WWW QBD COM 1 800 663 3005 TEL 905 459 0709 FAX 905 459 1478 info qbd com 08 2015 47 0480 192 N AC48 OPERATION MANUAL SAFETY INSTALLATION AND INSTRUCTIONS KEEP THE MANUAL FOR FUTURE...

Page 2: ...CTION 3 4 UNIT INSPECTION FOR ANY SHIPPING DAMAGE 5 5 SERIAL NUMBER 6 6 WARNING AND SAFETY LABELS 7 7 SAFETY INSTRUCTIONS DURING INSTALLATION AND USAGE 8 8 ELECTRICAL SAFETY INSTRUCTIONS 9 9 OPERATION...

Page 3: ...d in direct sunlight Cooler should not be installed near HVAC vents Cooler should not be installed near fans Cooler should not be installed near doorways Cooler should be leveled front to back and sid...

Page 4: ...the cooler for all your claims All goods are shipped at the customer s risk Return of goods to the factory must have the authorized approval of QBD No returns will be accepted after 10 days Any short...

Page 5: ...nstalling or servicing your unit QBD s assures a high quality product and if maintained properly will serve you with trouble free operation DANGER Indicates potentially hazardous situation which if ig...

Page 6: ...this manual in secure location and should be available for all the intended users and service technicians INTENDED USE QBD s cooler is designed for storage and or commercial merchandising of hazardous...

Page 7: ...l packages for damage to packaging material Damage to external packaging may have resulted in unit damage Check packages for all accessories and components including legs casters if applicable and she...

Page 8: ...respondence regarding the cooler Cooler Model __________________________________ Serial number __________________________________ This manual is only a reference document for installation use and serv...

Page 9: ...instructions CAUTION HOT ATTENTION CHAUD WWW QBD COM POWER SOURCE 220V 60Hz WWW QBD COM CONTACTOR RELAY CONNECTION BOX WWW QBD COM REFRIGERANT R 404A WWW QBD COM W A R N I N G THE THERMOSTAT CONTROL O...

Page 10: ...rect supply voltage low voltage or unstable supply voltage Don t install cooler where storage handling and or dispensing of flammable and or explosive material may occur Keep all the packing material...

Page 11: ...ted electrical circuit and ensure the voltage rating of the circuit is same as mentioned by manufacturer Don t use a power cord having cracks or abrasion mark All coolers are supplied with an appropri...

Page 12: ...SERVICE WARNING Cold controller is set to maintain the average cooler temperature at 3 3 C 38 F Any change in setting could result in poor performance and or component s failure Operating ambient cond...

Page 13: ...to allow shelf bracket bottom tab to clear shelf standard slot 3 Swing shelf bracket bottom tab into shelf standard slot 4 Place shelf panel on two brackets REMOVAL 1 Take the shelf panel off the brac...

Page 14: ...80 192 N 11 ELECTRONIC COLD CONTROL AC48 is installed with a customized Danfoss electronic cold control ERC112C with the following features 1 Precise temperature control 2 Adaptive defrost 3 Fan Contr...

Page 15: ...set point Press up 3 down 4 to adjust set point Press UP 3 for warmer setting or DOWN 4 for colder setting After 30 seconds the display automatically reverts to show the current temperature and SET PO...

Page 16: ...ler is damaged or faulty Display will show S1 for cabinet temperature control probe fault Display will show S2 for defrost control probe fault CONTROLLER INFORMATION ATTACHED WITH COOLER Controller pa...

Page 17: ...power to the unit 2 In order to access the condenser coil remove the front grill by lifting up and pulling out the bottom side as shown on the left 3 Carefully vacuum or brush the front surface of co...

Page 18: ...nd power switches and remove all products from unit Allow sufficient time for the unit to reach room temperature before proceeding with cleaning CAUTION Remove all products from unit before proceeding...

Page 19: ...LURE Danfoss controller is used to control the compressor and defrost cycle under controlled ambient conditions The controller is programmed for a defrost cycle of 30 minutes for every 6 hours The mai...

Page 20: ...QBD COOLING SYSTEMS INC 18 08 2015 47 0480 192 N CONDENSING UNIT WIRING DIAGRAM...

Page 21: ...verload Repair or replace control Re assure the control probe location Check wiring against diagram Repair or replace the LP HP switch Replace the controller Replace the switch Compressor will not sta...

Page 22: ...e overload protector Excess current passing through overload Low unstable voltage Overload failed Capacitor fault Excessive discharge Suction pressure too high Compressor overheating Compressor electr...

Page 23: ...d Correct the charge Leaking Water Very Humid Conditions Blocked Drain Electrical condensate pan failure Clear blocked drains Repair and replace electrical condensate pan Evaporator Freeze Up Temperat...

Reviews: