4

5

INSTALLATION AND OPERATION MANUAL SOLAR MODULES GENERATION 4 (G4) – HANWHA Q CELLS – NA

INSTALLATION AND OPERATION MANUAL SOLAR MODULES GENERATION 4 (G4) – HANWHA Q CELLS – NA

For the electrical data and additional information of the solar modules please refer to the respective currently valid data sheets available at 
www.q-cells.com.

PRODUCT LINE

Q.PRO-G4 / Q.PRO BFR-G4 /
Q.PRO BLK-G4 / Q.PRO BFR-G4.1

Q.PLUS BFR-G4.1 

Cell type

Polycrystalline

Q.ANTUM

Length [

in

 (mm)]

65.7 (1670)

65.7 (1670)

Width [

in

 (mm)]

39.4 (1000)

39.4 (1000)

Height [

in

 (mm)]

1.26 (32)

1.26 (32)

Area [yd² (m²)]

2 (1.67)

2 (1.67)

Weight [lbs (kg)]

41.45 (18.8)

41.45 (18.8)

Max. system voltage V

SYS

 [V]

1000

1000

Max. series fuse rating [A]

20

20

Permissible operating  

temperature range [°F (°C)]

–40 to +185 (–40 to +85)

Junction box protection class

IP67 with bypass diode

Connector protection class

IP68

IP68

Fire protection class

C, Type 1

C, Type 1

Snow load [Pa]

1

5,400

5,400

Wind load [Pa]

1

4,000

4,000

Certificates

UL 1703; VDE Quality Tested; CE-compliant; IEC 61215 (Ed.2)

see page 9 et sqq.; 

IEC 61730 (Ed.1) Application Class A

1  

Test-load in accordance with IEC 61215

Validity

These instructions are only valid for crystalline solar modules from 
Q CELLS. Q CELLS assumes no liability for damage resulting from 
failure to observe these instructions. 

 

Ä

Please observe the wiring and dimensioning of the system.

 

Ä

The installer of the system is responsible for compliance with all 
necessary safety regulations during set-up and installation.

Q CELLS assumes no liability on the basis of these instructions. 
Q CELLS is only liable in the context of contractual agreements or 
in the context of accepted guarantees. Q CELLS accepts no other 
responsibility for the functionality and safety of the modules. 

 

Ä

Please observe the instructions for any other system components 
that may be part of the complete solar power system. It may be 
necessary to carry out a structural analysis for the entire project. 

 

Ä

If your questions are not satisfactorily answered in the manual, 
please contact your system supplier. 

Additional information can be found on our website at: 
www.q-cells.com. 

Information for the Operator

 

Ä

Please keep this manual for the entire life of the solar power 
system.

 

Ä

Please contact your system supplier for information concerning 
the formal requirements for solar power systems.

 

Ä

Please be sure to contact the relevant local authorities and energy 
providers regarding regulations and permit requirements prior 

to installation of the solar power system. Your financial success 
depends on the fulfillment of these requirements. 

Other applicable documents

This installation manual is only valid in combination with the 
following technical information.

DOCUMENT TYPE

Product data sheet

Packaging and transport information

 

MISUSE OR INCORRECT USE OF SOLAR MODULES VOIDS THE 
LIMITED WARRANTY AND MAY CREATE A SAFETY HAZARD 
AND RISK PROPERTY DAMAGE. THIS INCLUDES IMPROPER 
INSTALLATION OR CONFIGURATION, IM PROPER MAINTENANCE, 
UNINTENDED USE, AND UNAUTHORIZED MODIFICATION. 

1 INTRODUCTION

2.1  Technical specifications

2 PLANNING

Fig. 1: 

 External dimensions (in inch (mm)) and components for Q.PRO-G4, Q.PRO BFR-G4, Q.PRO BLK-G4, 

 

Q.PRO BFR-G4.1, Q.PLUS BFR-G4.1

NA

DETAIL A

0.630" (16 mm)

0.335" (8.5 mm)

0.965" (24.5 mm)

Junction bo×

Product label

38.58" (980 mm)

65.7" (1670 mm) 

4 × Fastening points (DETAIL A)

Cable with
connectors

Frame

5.90" (150 

mm)

39.4" (1000 mm)

37.44" (951 mm)

1.26" (32 mm)

8 × Drainage holes

6 × Grounding points ø 0.177" (4.5 mm)

39.37" (1000 mm)

Summary of Contents for Q.PRO BFR-G4.1

Page 1: ...Valid for North America Q PRO G4 Q PRO BFR G4 1 Q PRO BLK G4 Q PLUS BFR G4 1 INSTALLATION AND OPERATION MANUAL...

Page 2: ...check the results of said procedure Prohibited Beware of possible danger or damage Categories Danger Risk of fatal injury Attention Risk of serious injury or damage to property Note Risk of damage to...

Page 3: ...rantees Q CELLS accepts no other responsibility for the functionality and safety of the modules Please observe the instructions for any other system components that may be part of the complete solar p...

Page 4: ...he mounting frame are compatible Clamp System Requirements Use customary clamps that satisfy the following requirements Clamp width 1 57in 40 mm Clamp height compliant with a 1 26in 32 mm frame height...

Page 5: ...structure support Push 0 3 94 0 100 1200 2400 2400 Pull 0 3 94 0 100 1100 1 Distance between outer edge of module and middle of the clamp Describes the maximum module surface load vertical to the modu...

Page 6: ...nal multiplying factor of 125 percent 80 percent derating which might be applicable Please follow the valid national guidelines for the installation of electrical systems refer to section 690 8 of the...

Page 7: ...own NOTE Module damage may occur Never step on modules Do not subject modules to any mechanical stress Do not allow any objects to fall onto modules 3 1 Safety and transport 3 INSTALLATION DANGER Risk...

Page 8: ...m the separation of a closed circuit These can result in life threatening injuries The danger increases when several modules are connected in series Please be aware of that the entire open circuit vol...

Page 9: ...and qualified tools of the manufacturer Tyco Amphenol or Multicontact 2 Cover the modules to be disconnected 4 2 Electrical installation safety 4 ELECTRICAL CONNECTION Use solar cables for the connec...

Page 10: ...factors Option A Use of a grounding lug A listed grounding lug can be bonded to the frame using the grounding holes pre drilled in the frame These holes are marked Dimensions shown are in inches 0 1 7...

Page 11: ...ry due to hot and live modules Only clean modules that have cooled down Do not carry or wear any electrically conductive parts WARNING Risk of falling due to unsecured access Never access the installa...

Page 12: ...CA INC 300 Spectrum Center Drive Suite 1250 Irvine CA 92618 USA TEL 1 848 748 59 96 EMAIL inquiry us q cells com WEB www q cells us Subject to change without notice Hanwha Q CELLS Installation manual...