Page: 6
XD10TTAM
3. Blocking (via MW)
ON
= Blocking disabled
OFF
=Blocking enabled when
system disarmed (see DIP4 /
DIP6 has to be ON)
4. RI 1 mode
ON
= RI disabled
OFF
= RI enabled
RI is used to enable the Anti-masking and
Blocking feature when DIP2 and DIP3 are
programmed to
OFF
. It is required to connect
the RI input to an output that follows the Arm/
Disarm status of the panel and gives Negative
(0v/-/GND) when disarmed and Positive
(COM/+/12v) when armed.
7. Buzzer Alarm
OFF
= Anti-mask enabled only
system disarmed (see DIP4)
6. Open Mask and Alarm Relays
5. Sensitivity
OFF
= Mask relay open
ON
= Buzzer Enabled
OFF
= Buzzer Disabled
ON
= Mask & alarm relays open
8. LED Enable/Disable
ON
= Auto Sensitivity
OFF
= High Sensitivity
ON
= LED Enabled (Remote LED disabled)
OFF
= LED Disabled (Remote LED enabled)
To remotely enable the LEDs:
Connect LED to walk test PGM:
0V
= Walk Test On.
12V
= Walk Test Off
5. Dip Switch Programming
1. 50/60Hz AC Filter
ON
= 50Hz.
OFF
= 60Hz (For use with AC supplies at 60Hz)
2. Anti-Mask Operation
ON
= Anti-mask enabled
Summary of Contents for XD10TTAM
Page 1: ...10m Pet Immune External Detector RINS1398 4 POLISH ITALIAN GREEK ENGLISH RUSSIAN SPANISH...
Page 14: ...XD10TTAM 14 2 XD10TTAM 0 1 LED 1 2 30 Mask Alarm LED 1 a Alarm LED XD...
Page 41: ...XD10TTAM 41 RUSSIAN 2 XD10TTAM AM 0 1 1 2 30 30 3 1 XD XD XD 3 XD of XD...
Page 46: ...XD10TTAM 46 8...
Page 58: ...Notes...
Page 59: ...Notes...