1-5-1
E9A80PFS
PREPARATION FOR SERVICING
How to Enter the Service Mode
About Optical Sensors
Caution:
An optical sensor system is used for the Tape Start
and End Sensors on this equipment. Carefully read
and follow the instructions below. Otherwise the unit
may operate erratically.
What to do for preparation
Insert a tape into the Deck Mechanism Assembly and
press the PLAY button. The tape will be loaded into
the Deck Mechanism Assembly. Make sure the power
is on, connect TP502 (S-INH) to GND. This will stop
the function of Tape Start Sensor, Tape End Sensor
and Reel Sensors. (If these TPs are connected before
plugging in the unit, the function of the sensors will
stay valid.) See Fig. 1.
Note:
Because the Tape End Sensors are inactive, do
not run a tape all the way to the start or the end of the
tape to avoid tape damage.
Q504
Q503
TP502
S-INH
Fig. 1
Summary of Contents for PY90VG
Page 37: ...1 12 3 Main 1 7 Schematic Diagram VCR Section E9A12SCM1 ...
Page 39: ...1 12 5 Main 3 7 Schematic Diagram VCR Section E9A12SCM3 ...
Page 40: ...1 12 6 Main 4 7 Schematic Diagram VCR Section E9A12SCM4 ...
Page 41: ...1 12 7 Main 5 7 Schematic Diagram VCR Section E9A12SCM5 ...
Page 42: ...1 12 8 Main 6 7 Schematic Diagram VCR Section E9A12SCM6 ...
Page 43: ...1 12 9 Main 7 7 Schematic Diagram VCR Section E9A12SCM7 ...
Page 45: ...1 12 11 Front Jack Schematic Diagram VCR Section E9A12SCJK ...
Page 83: ...PY90VG E9A12UD 2006 06 15 ...