1-12-19
BE9A00F01021A
Power Supply CBA Top View
"Ce symbole reprèsente un fusible à fusion rapide."
CAUTION !
For continued protection against fire hazard,
replace only with the same type fuse.
ATTENTION : Pour une protection continue les risqes
d'Incele n'utiliser que des fusible de m
ê
me type.
Risk of fire
-replace fuse as marked.
"This symbol means fast operating fuse."
A V
F
Because a hot chassis ground is present in the power
supply circut, an isolation transformer must be used.
Also, in order to have the ability to increase the input
slowly, when troubleshooting this type power supply
circuit, a variable isolation transformer is required.
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F1001) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
Summary of Contents for PY90VG
Page 37: ...1 12 3 Main 1 7 Schematic Diagram VCR Section E9A12SCM1 ...
Page 39: ...1 12 5 Main 3 7 Schematic Diagram VCR Section E9A12SCM3 ...
Page 40: ...1 12 6 Main 4 7 Schematic Diagram VCR Section E9A12SCM4 ...
Page 41: ...1 12 7 Main 5 7 Schematic Diagram VCR Section E9A12SCM5 ...
Page 42: ...1 12 8 Main 6 7 Schematic Diagram VCR Section E9A12SCM6 ...
Page 43: ...1 12 9 Main 7 7 Schematic Diagram VCR Section E9A12SCM7 ...
Page 45: ...1 12 11 Front Jack Schematic Diagram VCR Section E9A12SCJK ...
Page 83: ...PY90VG E9A12UD 2006 06 15 ...