shall be 0.2MPa. It is ok if no leakage found within 3 minutes.

3. If the pump will not be used for a long time, Remove it from the water, and run it in clean water 

for several minutes to clean its inside and outside. Then dry and do antirust treatment. If neces-

sary, repaint it.

5. TROUBLE SHOOTING

TROUBLE

CAUSE

SOLUTION

Diffi  cult to start

1. Voltage too low

2. Phase lost

3. Impeller stuck

4. Cable too thin

5. Stator winding burnt

1. Adjust Voltage to 0.9-1.1 times 

of the rated range.

2. Check the wire in the switch and 

cable.

3. Clean the impeller.

4. Use the proper cable.

5. Rewind or replace.

Low capacity

1. head too high.

2. Strainer or inlet clogged.

3. Impeller worn out.

4. Submersion too shallow or air

sucked in.

5. Impeller runs in reverse direction.

1. Use in the head range.

2. Clean the inlet or Strainer.

3. Replace the impeller.

4. Keep enough submersion depth.

5. Swap any two of the phases.

Unexpected

stop

1. Protector Works

2. Impeller stuck

3. Stator winding burnt

1. Check the protector.

2. Clean the impeller.

3. Rewind or replace.

Stator winding

burnt

1. Run too log time with phase lost.

2. Short circuit in winding or between

phases due to leakage.

3. Impeller stuck

4. Pump starts too frequently.

5. Pump runs overloaded.

1. Rewind or overhaul

2. Solve the problems with mecha-

nical seal.

3. Clean the impeller.

4. Use in proper way.

Summary of Contents for WQ Series

Page 1: ...Por favor lea atentamente este manual antes del uso del equipo MANUAL DE INSTALACIÓN Y MANTENIMIENTO Serie WQ BOMBAS DE AGUA SUMERGIBLE ...

Page 2: ...roducto tenga en cuenta que los productos eléctricos baterías o cables no deben desecharse junto con la basura doméstica Recicle donde existan instalaciones adecuadas para ello consulte con su autoridad local para obtener consejos de reciclaje El abandono o la eliminación incontrolada de residuos puede causar daños al medio ambiente y a la salud humana Por lo que al reciclar este producto de maner...

Page 3: ...ableado 2 Antes de arrancar asegúrese de que la resistencia de aislamiento sea superior a 2 MΩ 3 Antes de la inmersión se requiere una prueba para ver si el giro está en la dirección correcta Si no apague la corriente intercambie cualquiera de las tres fases Por favor pruébela durante un minuto 4 Conecte y sujete la manguera apropiada diámetro igual que el tamaño de salida a la junta de salida No ...

Page 4: ...ble y el inte rruptor del cable 3 Limpie el impulsor 4 Use el cable apropiado 5 Rebobine o cambie el estator Baja capacidad de bombeo 1 Cabezal demasiado alta 2 Filtro o entrada obstruidos 3 Impulsor degastado 4 Inmersión demasiado alta o succión de aire 5 Impulsor gira en sentido inverso 1 Use el cabezal en su rango 2 Limpie el filtro o la entrada 3 Sustituya el impulsor 4 Mantenga suficiente profu...

Page 5: ...Polígono Indsutrial Oeste parc 25 12 30169 San Ginés Murcia Tlf 968 88 08 52 Fax 968 09 84 www proindecsa com proindecsa proindecsa com ...

Page 6: ...Please clearly read the manual before use the motor OPERATING AND MAINTENANCE MANUAL Serie WQ SUBMERSIBLE SEWAGE PUMP ...

Page 7: ...www proindecsa com proindecsa proindecsa com OPERATING AND MAINTENANCE MANUAL SERIE WQ 7 CONTENTS 8 8 8 8 9 1 WARNING 2 CONDITIONS OF USE 3 INSTALLATION AND NOTICE 4 MAINTENANCE 5 TROUBLE SHOOTING ...

Page 8: ... on the pump to make sure of no damage during transportation or storage especially the cable 2 Before Starting make sure that the insulation resistance should be over 2 MΩ 3 Before immersion trial run is required to see whether the rotation is in correct direction If not turn off the power swap any two of the three phases Please finish the trial run within one minute 4 Connect and fasten proper Dia...

Page 9: ...and cable 3 Clean the impeller 4 Use the proper cable 5 Rewind or replace Low capacity 1 head too high 2 Strainer or inlet clogged 3 Impeller worn out 4 Submersion too shallow or air sucked in 5 Impeller runs in reverse direction 1 Use in the head range 2 Clean the inlet or Strainer 3 Replace the impeller 4 Keep enough submersion depth 5 Swap any two of the phases Unexpected stop 1 Protector Works...

Page 10: ...Polígono Indsutrial Oeste parc 25 12 30169 San Ginés Murcia Tlf 968 88 08 52 Fax 968 09 84 www proindecsa com proindecsa proindecsa com ...

Page 11: ...Veuillez lire attentivement le manuel avant d utiliser la pompe INSTRUCTIONS D UTILISATION ET MAINTENANCE Serie WQ POMPE SUBMERSIBLE ...

Page 12: ... proindecsa com proindecsa proindecsa com INSTRUCTIONS D UTILISATION ET MAINTENANCE SERIE WQ 12 CONTENU 8 8 8 8 9 1 AVERTISSEMENT 2 CONDITIONS D UTILISATION 3 INSTALLATION ET AVIS 4 MAINTENANCE 5 DÉPANNAGE ...

Page 13: ...le transport ou le stockage en particulier le câble 2 Avant de commencer assurez vous que la résistance d isolement est supérieure à 2 MΩ 3 Avant l immersion un essai de fonctionnement est nécessaire pour voir si la rotation est dans le bon sens Si ce n est pas le cas coupez l alimentation échangez deux des trois phases Veuillez terminer l essai de fonctionnement dans la minute qui suit 4 Connecte...

Page 14: ...a plage nominale 2 Vérifiez le fil dans l interrupteur et le câble 3 Nettoyez la roue à aubes 4 Utilisez le câble approprié 5 Rembobinez ou remplacez Faible capacité 1 tête trop haute 2 Crépine ou entrée bouchée 3 Impulseur usé 4 Immersion trop peu profonde ou air aspiré 5 La turbine fonctionne en sens inverse 1 Utilisation dans la gamme des têtes 2 Nettoyer l entrée ou la crépine 3 Remplacer l impu...

Page 15: ...Polígono Indsutrial Oeste parc 25 12 30169 San Ginés Murcia Tlf 968 88 08 52 Fax 968 09 84 www proindecsa com proindecsa proindecsa com ...

Reviews: