Parameter name
PiD
Description
DEVICE_LABEL *
0x0082
additional device description;
It is possible to enter an additional
device description using up to
32 ASCII characters
DMX_PERSONALITY *
0x00E0 DMX operational mode
SENSOR_DEFINITION
0x0200 information on the selected
temperature sensor
SENSOR_VALUE
0x0201 information about sensors
DEVICE_HOURS
0x0400 operating time counted
CONTROL_HOURS
0x0401 time of channel control
DIGITAL_MODE
0x8039 setting the control mode of the
channel with the buttons
DIGITAL_RISE_TIME *
0x8056 setting the rise time for control
with the buttons in range 0 – 24h
DIGITAL_LAST_TIME *
0x8057
setting the duration for control with
the buttons in range 0 – 24h or
infinity (0xFFFFFFFF)
DIGITAL_FALL_TIME *
0x8058 setting the fall time for control with
the buttons in range 0 – 24h
DIGITAL_MIN_LEVEL *
0x8059
setting the minimum level which
can be reached while dimming for
the control mode with the buttons
in range 0 – 50%
OUTPUT_CURVE *
0x8049 selection of the control curve in
range 0 – 24h
OUTPUT_CURVE_INVERT *
0x804F
selection of the invert function for
the previously set
0 – normal, 1 – inverted
25