background image

PX714

Driver LED

4 x 350mA/48V

User manual

Summary of Contents for PX714

Page 1: ...PX714 Driver LED 4 x 350mA 48V User manual...

Page 2: ...l response 14 5 6 Description of programs 15 5 7 Master Slave function 17 5 8 White balance 18 5 9 Smooth 19 5 10 Light control frequency 20 5 11 Screen saving screen blanking 21 5 12 Temperatures lim...

Page 3: ...rves the right to make modifications in order to improve device operation PXM Marek upnik sp k Pod e 654 32 003 Pod e BDO register number 000005972 tel 48 12 385 83 06 mail info pxm pl www pxm pl Rev...

Page 4: ...of the 256 colors define by the manufacturer 3b each color RGB can be set separately 3bd each color RGB can be set separately and dimmer dimming all outputs 4b each color RGBW can be set separately 4b...

Page 5: ...ved 1 The device may only be connected to 12 48V DC with current carrying capacity compatible with technical data 2 All the conductors should be protected against mechanical and thermal damage 3 In th...

Page 6: ...evice a basic item in the MENU setting parameters for all channels simultaneously setting parameters for each channel individually inverting the meter display 180 degrees DMX address setting control m...

Page 7: ...ess settings for first channel Master mode on off number of channels being sent in the Master mode white colour balance setting red balance green balance blue balance white balance white colour balanc...

Page 8: ...y the sensor temperature limit is switched off and it is not possible to read the following temperatures maximum minimum and current or when a mode which does not use all channels is set and unused ch...

Page 9: ...nd confirms changes made 5 2 Group DMX address settings The menu of the PX714 driver allows for setting the DMX address within a range between 1 and 505 511 depending on work mode of device For exampl...

Page 10: ...ny DMX address to every output channel The simplest example of implementation of this function is to control the lightness of one color LEDs connected to all outputs In such case the same address must...

Page 11: ...1 ENTER NEXT ENTER ENTER NEXT NEXT NEXT NEXT NEXT NEXT NEXT The PX714 driver can operate in different control modes Depending on the selected mode the devices takes up a different numbers of channels...

Page 12: ...e settings table is on the next page Channel 1 red colour Channel 2 green colour Channel 3 blue colour Channel 4 white colour Channel 5 operating mode selection Channel 6 speed settings higher value q...

Page 13: ...40 47 Program 6 x x x 48 55 Program 7 x x x 56 63 Program 8 x x x 64 71 Program 9 x x x 72 79 Program 10 x x x 80 87 Program 11 x x x 88 95 Program 12 x x x 96 103 Program 13 x x x 104 111 Program 14...

Page 14: ...DMX signal will automatically break the realized function and the module will once again follow the commands transmitted via the DMX line P01 P18 choosing a ready program provided in the device softw...

Page 15: ...ctivation of all outputs at 100 with the possibility of setting the switch on time SPd all outputs after decay DMX signal oFF disabling all outputs after DMX signal loss 5 6 Description of programs Th...

Page 16: ...55 0 255 255 0 0 0 G 255 255 0 0 255 0 255 255 0 B 0 0 0 255 0 255 0 0 255 W 0 0 0 0 0 0 255 0 0 Step 3 R 0 255 0 0 0 0 255 G 0 0 0 0 255 0 255 B 255 0 0 0 0 255 0 W 0 0 255 0 255 0 0 Step 4 R 0 0 0 0...

Page 17: ...ep 4 R 255 0 0 127 G 0 255 127 0 B 127 127 255 127 W 0 0 0 0 5 7 Master Slave function The PX714 module has a built in DMX 512 receiver and can be controlled from any desktop or controller running in...

Page 18: ...ng an external controller 5 8 White balance Sometimes there can be problems with getting white colour on the RGBW series LEDs This may be a result of using diodes with different technical parameters F...

Page 19: ...etween the DMX signal packets for the selected option or the time interval set in the menu in range 10 999ms The smooth function may slightly slow down the lamp s response rate to changes in the DMX s...

Page 20: ...ing effect which is caused by improper signal synchronization that controls the LEDs The user can choose from the available frequency range from 366Hz up to 25 0kHz which can be smoothly changed using...

Page 21: ...ithout interfering with other parameters Press any key to restore the backlight 5 12 Temperatures limits and sensor failure PX714 has been equipped with a function that limits the output power dependi...

Page 22: ...ue can be set between 30 C and 60 C Hi maximum limit temperature value set in the range from 70 up to 90 C t C current temperature tSH the highest temperature recorded by the sensor tSL the lowest tem...

Page 23: ...ensor or disable the temperature limit 5 13 Display function As the driver should be installed As far as possible in a small distance from the controlled LEDs the lack of space may force the necessity...

Page 24: ...t possible to enter a particular menu level or it is necessary to restore the device to its default settings follow the instructions below In the first case when a particular menu level cannot be acce...

Page 25: ...d If this message is accepted by pressing enter the default settings will be restored The user can also exit this menu level without restoring the default settings In order to do this press the escape...

Page 26: ...he Err message remains on the screen the memory is permanently damaged and the unit must be sent to the service point 6 DMX signal connecting PX714 have to be connected to DMX line in serial mode with...

Page 27: ...ol List of RDM parameters supported by the PX714 Parameter name PiD Description SUPPORTED_PARAMETERS 0x0050 all supported parameters PARAMETER_DESCRIPTION 0x0051 description of additional parameters D...

Page 28: ...TEMPERATURE_LIMIT_ ON OFF 0x800E temperature limitation activation for the temperature sensor connected to the driver TEMPERATURE_ THRESHOLD_LOW 0x800F lower temperature value for which the temperatu...

Page 29: ...ttings of green channel value for scene saved in PX714 SCENE_BLUE 0x801F settings of blue channel value for scene saved in PX714 SCENE_WHITE 0x8020 settings of white channel value for scene saved in P...

Page 30: ...8 Programming 30 ENTER ENTER NEXT ENTER NEXT NEXT ENTER NEXT NEXT NEXT ENTER NEXT NEXT NEXT NEXT ENTER ENTER NEXT NEXT NEXT ENTER NEXT ENTER ENTER NEXT NEXT NEXT Next page NEXT NEXT NEXT NEXT NEXT...

Page 31: ...31 ENTER ENTER NEXT NEXT NEXT ENTER NEXT NEXT ENTER NEXT NEXT ENTER NEXT ENTER NEXT NEXT NEXT NEXT NEXT ENTER NEXT NEXT NEXT NEXT NEXT NEXT Previous page...

Page 32: ...rome lamp connection one colour 350mA power supply LED driver Power supply Number of diodes of one color LED driver Power supply Number of diodes of one color PX714 12V 1 3 PX714 12V 3 24V 4 6 24V 6 4...

Page 33: ...only in series controlled LEDs can be connected using two conductors only i e two per channel the number of serially connected LEDs depends on the driver and supply voltage 33 LED lamp RGBW WHITE GRE...

Page 34: ...he connection of the NTC 4K7 thermistor is applicable only when one lamp is connected to the driver This is due to the fact that the device can read the temperature from only one lamp 34 PX714 driver...

Page 35: ...Monochrome lamp in DW mode connection diagram 35 RED cold white PX714 driver warm white cold white warm white WHITE GREEN BLUE WHITE BLUE GREEN RED...

Page 36: ...l support yes power supply 12 48V DC max current consumption max 1 4A power consumption without load 1W output channels number 4 control accuracy 16 bit programmable scenes 1 built in programs 18 outp...

Page 37: ...output sockets PCB terminal block Push button 0 5 1 5mm2 Master mode yes weight 0 2kg dimensions width 192mm height 44 8mm depth 20 6mm 37...

Page 38: ...0 2018 EN 61000 4 2 2009 EN IEC 61000 6 1 2019 EN 61000 6 3 2007 and meets the essential requirements of the following directives 2011 65 UE DIRECTIVE OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of...