In the case of the “
Write Single Register
” command, the Modbus input is
treated as a multi0value input with 512 channels. The parameters of each
channel are set in the same manner as in the case of a DMX input.
b) Returned states
Element
Size
Description
Scene status data
2B
state
2B
master
4B
time left [ms]
8B
reserved
Program status data
2B
state
2B
master
2B
speed
2B
repeat count
2B
current step
3B
step time left [ms]
8B
reserved
Mask status data
2B
state
2B
master
4B
time left [ms]
8B
reserved
Sequence status data
2B
state
2B
current step
4B
time left [ms]
8B
reserved
47