Below there are presented Modbus commands supported by the controller:
a)
Commands
32
Modbus command
Controller reaction
standard
1
Read Coils
n
ot supported
3
Read Holding registers
r
eturns the state of digital inputs in bits
4
Read Input Registers
r
eturns the status of the controller
5
Write Single Coil
n
ot supported
6
Write Single Register
s
ets the value of a single input channel of the Modbus
15
Write Multiple Coils
not supported
16
Write Multiple Register
s
ets the value of many input channels of the Modbus
own
65
Internal event
t
riggers an internal event with no value, the argument is
the number of a virtual event
66
Internal event
t
riggers several internal events without values,
the arguments are the numbers of virtual events
67
Internal event
t
riggers an internal event with a value, the first argument
is the number of virtual events, the second is the value
of the event
68
Internal event
t
riggers several internal events with values, the
arguments are the numbers of virtual events
69
Action
t
riggers a specific action
70
Action
t
riggers many actions
In the case of the “Write single Register” command, the Modbus input is treated as a multi-value
input with 512 channels. The parameters of each channel are set in the same manner as in the
case of a DMX input.