8
Response to the loss of DMX signal
This function is used both to protect the system against the
disappearance of DMX signal and to gain a specific state on outputs. After it
has been activated, in case of a lack of DMX signal, the module will perform
the selected function by itself. The reconnecting of DMX signal will
automatically break the performed function, and the module will again be
controlled by DMX signal.
In order to start the function, enter
noS
option:
1. From the start menu go to the
noS
and press
enter
2. Use the
next
or
prev
buttons to select the device behavior for DMX
signal loss
The following options are available:
Pr1
–
Pr2
– starting program 1 or 2
on
– switching all outputs on 100%
oFF
– complete switch-off of outputs
HLd
– holding the last DMX value
Sc1
–
Sc4
– scene 1, 2, 3 or 4
Up to 10 steps can be created in the program (
F01
–
F10
), in each step it
is possible to define the values of output channels (
CH1
–
CH8
) in the range
from 0 to 255. Additionally, in each step you can define its duration (
Spd
) in
the range of 0,1 – 99,9 seconds. In the step it is also possible to set the
transition smoothness (
FAd
)
in the range from 0 (step transition) to 100
10