11
The next tab – [
Sensors
] – is used to check parameters of sensors installed in the device. These
may be, for example, temperature sensors. In addition to the current temperature, the program
displays information on the lowest and the highest recorded temperature. What is more, it
displays messages relating to the operation time of the product, such as: number of hours,
number of power cycles, and – for lamps – e.g. number of flashes.
Parameters relating to the lamps (at the very bottom of the window), i.e. [
Hours
] refer to the total
number of hours of lamp operation (time when it was on). Another parameter [
Strikes
] informs
about the number of lamp activations.
The last value [
Stat
e
] signals the following situations:
!
LAMP_OFF -
lamp is off
!
LAMP_ON -
lamp is on
!
LAMP_STRIKE -
activation of discharge lamps (applies to discharge lamps)
!
LAMP_STAND BY -
reduced lamp power, standby mode
!
LAMP_NOT_PRESENT -
lamp is not connected
!
LAMP_ERROR -
lamp communication error
5.2.2. Sensors
The [
Sliders
] tab allows you to change the values of the pre-selected devices or slave devices