External button control
Control function executed with external button no. 1
Maximum brightness duration time for button control
Temperature sensor fail – contact service for repair
Analog mode – selecting this option in the main menu activates
analog control mode (also in the
noS
mode)
5
Dimmer programming
After turning the device on, software version is shortly displayed. During
the device normal operation the display shows DMX address or displays
AdC
lettering, meaning analog control mode. Pressing
Esc
during normal operation
will test the display – all the segments should get
On
state. Press
Enter
to
switch to the main menu, the display will show
ALL
. Press
Prev
or
Next
to
select programming menu (
ALL
,
Ind
,
AdC
,
dEF
), and then press
Enter
to
confirm your selection.
6
Programmable parameters
The parameters you can program for the dimmer include:
1. Group parameters –
ALL –
settings are the same for all the channels.
For DMX address setting it means that address displayed is the
address of the first channel. Programming DMX address in this menu
deletes the previously programmed individual addressing.
2. Individual parameters –
Ind
– each channel may be set with individual
parameters, including individual DMX addressing. The same address
9