background image

6

6. MASTER / SLAVE FEATURE

The PX307 driver is equipped with DMX-512 signal receiver and can be controlled with any DMX 

desktop. In addition, the unit has a built-in programmable reaction to DMX signal interruption 

(noS).  By  dint  of  18  factory-defined  programs  you  can  obtain  interesting  effects  without  the 

external controller. In case of using 

the complex installations realizing the same 

sequence cannot guarantee the full playing synchronization. That is why the driver is provided 

with the MASTER feature. When this feature is active, the module becomes the DMX signal 

transmitter  and  sends  to  all  the  other  modules  (set  as  SLAVES,  DMX  signal  receivers)  the 

realized program. Thanks to such a solution the precise synchronization, even in very complex 

installations, is possible.

few PX307 in 

To turn the MASTER feature on enter the  C-d  
menu

"

"

Press enter button to set a 

Con  option on the display.

"

"

To choose the number of DMX 
channels to be sent from PX307 You 
need to enter the  Chn  menu.

"

"

ENTER

ENTER

ENTER

NEXT

NEXT

You can activate Master 
function by setting it "on" 
or "oFF”

You can choose from 
range from 24 to 512.

NEXT

CAUTION:

PX307 basically sends three channels (R, G, B), but because the DMX standard defines the 

minimal emited channels number as 24, these three channels are duplicated eight times. If there 

is  such  a  necessity,  you  can  multiplicate  them  up  to  512  channels  (this  setting  is  not 

recommended because of the decrease of a transmission speed).

ENTER

NEXT

3x

5. DMX ADDRESS SETTING

The menu of the PX307 driver allows for setting the DMX address within a range between 1 and 
510. The driver occupies three consecutive DMX addresses. If address is set to 510, the last 
channel is occupied by address 512.

 

To set the DMX address:

1. Select Adr menu.

2. With "next" or "previous" buttons set the required DMX address.

1

2

NEXT

ENTER

ENTER

Summary of Contents for PiXiMo 3700

Page 1: ...MANUAL LED Driver 3 x 700 mA 24V DC PX307 R PiXiMo 3700...

Page 2: ...12 Temperature limitations 13 Er0 error message 14 Brightness control frequency 15 Display blanking 16 Smooth 17 Default settings and memory error Err 18 Programming 19 Connection scheme 20 Dimension...

Page 3: ...current carrying capacity enable activating large quantities of LEDs PX307 can be controlled by the DMX signal or it can work independently In this operation mode the user has access to a fully progr...

Page 4: ...SLAVE mode settings operation in BRIGHTNESS COLOUR mode operation in RGB mode turning all the outputs on at 100 setting the parameters for all channels concurrently 1 DMX 512 input 2 DMX 512 output 3...

Page 5: ...our setting during scene programming screen saver and DMX signal LED blanking turning ON OFF of MASTER mode setting the address of the first channel program no 17 memory error message restore default...

Page 6: ...e on enter the C d menu Press enter button to set a Con option on the display To choose the number of DMX channels to be sent from PX307 You need to enter the Chn menu ENTER ENTER ENTER NEXT NEXT You...

Page 7: ...e on oFF turns the white balance feature off PX307 can operate in HSL 4 channel 3 channel and 2 channel mode The HSL mode operates on 3 channels each channel regulates in turn hue saturation and light...

Page 8: ...ty to control the parameter of the selected mode EFF mode effect settings CHANNEL1 RED CHANNEL 2 GREEN CHANNEL 3 BLUE CHANNEL 5 SPEED CHANNEL 6 FADE CHANNEL 7 BRIGHTN x x x x x x x x x x x x x x x x x...

Page 9: ...of range of selected mode For example when you select mode only address 1 and 2 can be individually assign the selected value For the rest from to the unit displays a message that the address is out o...

Page 10: ...k 2 krok 3 krok 4 P11 P12 P13 P14 P15 P16 P17 P18 0 0 0 255 255 127 127 127 127 127 127 127 127 127 127 127 127 0 0 255 0 0 255 0 0 255 0 255 0 255 0 0 255 0 0 255 0 0 255 0 255 0 0 255 0 255 0 255 25...

Page 11: ...4 Similarly you can change the default values for temperature of activation 60 C by default and the maximum temperature 90 C by default function ENTER NEXT 4x 11 ENTER NEXT NEXT NEXT NEXT NEXT NEXT E...

Page 12: ...tivated display and LED will switch off after 25 seconds when no one in the same time will not press of any buttons of the PX307 Of course the device continues to work without interfering with the oth...

Page 13: ...ackets of DMX signal for selected option or within the time interval set in submenu _ NEXT NEXT ENTER Smoothing function in some cases may slightly slow down the rate of the reaction of end devices e...

Page 14: ...ver operating mode RGB 3b 3 byte master mode off number of sent DMX channels 128 white balance off no signal operating mode Program 1 smoothing function smooth off temperature limitation off 14 Err me...

Page 15: ...scrolls the menu backwards and decreases the parameters ENTER ENTER NEXT ENTER ENTER ENTER ENTER ENTER ENTER PREVIOUS NEXT NEXT NEXT NEXT NEXT NEXT NEXT NEXT NEXT NEXT ENTER ENTER ENTER NEXT ENTER NEX...

Page 16: ...ded conductors only CAUTION In case of voltage loss on one of the modules in a chain this one and the subsequent modules will not respond to a DMX signal Caution Temperature measurement will be correc...

Page 17: ...21 mm for 4 6 LEDs for channel DMX channels power supply current consumption no load current consumption output channels number outputs load capacity control accuracy programmable scenes built in pro...

Page 18: ...X connectors mgr in Marek upnik Name of producer Address of producer declares that the product Name of product Type answers the following product specifications LVD EMC Additional information Krak w 2...