background image

17. DEFAULT SETTINGS AND MEMORY ERROR (Err)

The device has a feature that allows for restoring default settings.
To use this option, PX307 must be disconnected from the power supply. Before restoring the 
power, press and hold the 

previous

 button. After turning the device on, the                 message will 

appear on the screen (when turning on the power until displaying the previous          message, 
the 

previous

 button have to be pressed).

This menu designation restores default settings. Accepting this message by pressing the 

enter

 

key restores default settings. It is also possible to exit this menu without returning to default 
settings by pressing the 

escape

 button.

The default settings in PX307 are as follows:

!

 DMX address - 1,

!

 driver operating mode - RGB (3b - 3-byte),

!

 master mode - off,

!

 number of sent DMX channels - 128,

!

 white balance - off

!

 no signal operating mode - Program 1

!

 smoothing function (smooth) - off

!

 temperature limitation - off

14

Err message - memory error

ENTER

POWER ON

HOLD PREVIOUS

ESCAPE

The device is equipped with a built-in memory work control function.
If there are problems with the memory operation on the PX308 display, the                 message 
appears - memory error.
In  this  situation,  select  the 

enter

  button. The  device  will  reload  the  default  configuration  and 

upload it to the memory. If after this operation, the                 message remains on the screen, the 
memory is permanently damaged and the unit must be sent to the service point.

There is also a different message informing about an error -           .
If this message is displayed, connect the temperature sensor (see diagram on page 16) or turn off 
the temperature limitation function (see section 12 on page 11).

Summary of Contents for PiXiMo 3700

Page 1: ...MANUAL LED Driver 3 x 700 mA 24V DC PX307 R PiXiMo 3700...

Page 2: ...12 Temperature limitations 13 Er0 error message 14 Brightness control frequency 15 Display blanking 16 Smooth 17 Default settings and memory error Err 18 Programming 19 Connection scheme 20 Dimension...

Page 3: ...current carrying capacity enable activating large quantities of LEDs PX307 can be controlled by the DMX signal or it can work independently In this operation mode the user has access to a fully progr...

Page 4: ...SLAVE mode settings operation in BRIGHTNESS COLOUR mode operation in RGB mode turning all the outputs on at 100 setting the parameters for all channels concurrently 1 DMX 512 input 2 DMX 512 output 3...

Page 5: ...our setting during scene programming screen saver and DMX signal LED blanking turning ON OFF of MASTER mode setting the address of the first channel program no 17 memory error message restore default...

Page 6: ...e on enter the C d menu Press enter button to set a Con option on the display To choose the number of DMX channels to be sent from PX307 You need to enter the Chn menu ENTER ENTER ENTER NEXT NEXT You...

Page 7: ...e on oFF turns the white balance feature off PX307 can operate in HSL 4 channel 3 channel and 2 channel mode The HSL mode operates on 3 channels each channel regulates in turn hue saturation and light...

Page 8: ...ty to control the parameter of the selected mode EFF mode effect settings CHANNEL1 RED CHANNEL 2 GREEN CHANNEL 3 BLUE CHANNEL 5 SPEED CHANNEL 6 FADE CHANNEL 7 BRIGHTN x x x x x x x x x x x x x x x x x...

Page 9: ...of range of selected mode For example when you select mode only address 1 and 2 can be individually assign the selected value For the rest from to the unit displays a message that the address is out o...

Page 10: ...k 2 krok 3 krok 4 P11 P12 P13 P14 P15 P16 P17 P18 0 0 0 255 255 127 127 127 127 127 127 127 127 127 127 127 127 0 0 255 0 0 255 0 0 255 0 255 0 255 0 0 255 0 0 255 0 0 255 0 255 0 0 255 0 255 0 255 25...

Page 11: ...4 Similarly you can change the default values for temperature of activation 60 C by default and the maximum temperature 90 C by default function ENTER NEXT 4x 11 ENTER NEXT NEXT NEXT NEXT NEXT NEXT E...

Page 12: ...tivated display and LED will switch off after 25 seconds when no one in the same time will not press of any buttons of the PX307 Of course the device continues to work without interfering with the oth...

Page 13: ...ackets of DMX signal for selected option or within the time interval set in submenu _ NEXT NEXT ENTER Smoothing function in some cases may slightly slow down the rate of the reaction of end devices e...

Page 14: ...ver operating mode RGB 3b 3 byte master mode off number of sent DMX channels 128 white balance off no signal operating mode Program 1 smoothing function smooth off temperature limitation off 14 Err me...

Page 15: ...scrolls the menu backwards and decreases the parameters ENTER ENTER NEXT ENTER ENTER ENTER ENTER ENTER ENTER PREVIOUS NEXT NEXT NEXT NEXT NEXT NEXT NEXT NEXT NEXT NEXT ENTER ENTER ENTER NEXT ENTER NEX...

Page 16: ...ded conductors only CAUTION In case of voltage loss on one of the modules in a chain this one and the subsequent modules will not respond to a DMX signal Caution Temperature measurement will be correc...

Page 17: ...21 mm for 4 6 LEDs for channel DMX channels power supply current consumption no load current consumption output channels number outputs load capacity control accuracy programmable scenes built in pro...

Page 18: ...X connectors mgr in Marek upnik Name of producer Address of producer declares that the product Name of product Type answers the following product specifications LVD EMC Additional information Krak w 2...

Reviews: