17. DEFAULT SETTINGS AND MEMORY ERROR (Err)
The device has a feature that allows for restoring default settings.
To use this option, PX307 must be disconnected from the power supply. Before restoring the
power, press and hold the
previous
button. After turning the device on, the message will
appear on the screen (when turning on the power until displaying the previous message,
the
previous
button have to be pressed).
This menu designation restores default settings. Accepting this message by pressing the
enter
key restores default settings. It is also possible to exit this menu without returning to default
settings by pressing the
escape
button.
The default settings in PX307 are as follows:
!
DMX address - 1,
!
driver operating mode - RGB (3b - 3-byte),
!
master mode - off,
!
number of sent DMX channels - 128,
!
white balance - off
!
no signal operating mode - Program 1
!
smoothing function (smooth) - off
!
temperature limitation - off
14
Err message - memory error
ENTER
POWER ON
HOLD PREVIOUS
ESCAPE
The device is equipped with a built-in memory work control function.
If there are problems with the memory operation on the PX308 display, the message
appears - memory error.
In this situation, select the
enter
button. The device will reload the default configuration and
upload it to the memory. If after this operation, the message remains on the screen, the
memory is permanently damaged and the unit must be sent to the service point.
There is also a different message informing about an error - .
If this message is displayed, connect the temperature sensor (see diagram on page 16) or turn off
the temperature limitation function (see section 12 on page 11).