S
SPECIFICATIONS
IGNITION
ELECTRICAL
FUEL
PARAFFIN
SUITABLE SPACE MIN-MAX
48 - 120 m
3
(20 - 49 m
2
)
HEATING CAPACITY MIN-MAX
1.5 kW (125 g/h) 3.0 kW (250 g/h)
MAINS
230 V~ / 50 Hz
ELE
CTRIC CONSUMPTION BURNING
22 W
ELECTRIC CONSUMPTION IGNITION
660 W
ELECTRIC CONSUMPTION
QUICK IGNITION MODE
100 W (heater not burning)
WEIGHT
10 kg
FUSE RATING
5 A / AC 250 V / 5 X 20 mm
DIMENSIONS (HxWxD)
45.5 x 40.0 x 30.7 cm
ACCESSORIES
TRANSPORTATION CAP
REMOVABLE TANK CAPACITY
5.8 LITRES
BURNING TIME PER TANK
(100% CAPACITY)
18.5 h
Specified values are indicative
Monitoring of the quality of ventilation (air renewal):
Direct measurement of the CO
2
level (NDIR CO
2
-sensor
S
).
T
WARRANTy PROVISIONS
Your heater comes with a 24-month warranty starting on the date of purchase.
Within this period all defects in material or workmanship will be repaired without
any charge. The following provisions shall apply regarding this warranty:
1
We expressly dismiss all other claims for damages, including consequential
damages.
2
Any repairs or replacements of components within the term of warranty will
not result in an extension of the term of warranty.
3
The warranty shall no longer apply, when the heater has been modified,
non-original parts have been used, or when it is repaired by third parties.
4
The warranty shall not apply to parts that are subject to normal wear.
5
The warranty shall only apply, when you present the original, dated proof of
purchase, provided no changes have been made to it.
6
The warranty shall not apply to damages caused by actions not in compliance
with this operating manual, neglect, and the use of an incorrect type of fuel,
or fuel past its use-by date. The use of incorrect fuel can even be dangerous*.