Installation Guide / SolarRoof™ Slate Tile
8
Code-Compliant Planning and Installation Guide V1.0 - Complying with AS/NZS1170.2-2011 AMDT 2-2016
- Installation Instructions -
5) Adjust the position of rubber seal on the hanger bolt (ER-HB-8/150)
to ensure hanger bolt have minimum 25 mm penetration depth into the
wood purlin.
Drive the hanger bolt on the wood purlin till the rubber seal is firmly
flush on the tile and turn the nut down till touching the rubber seal.
Please turn another 4 threads cycle to press the rubber seal.
Note:
1) Purlin thickness and tile thickness need to be verified to decide
position of rubber seal for appropriate penetration depth;
2) It is recommended to apply Sikaflex on the area around 10 mm hole
of the tile before fixing hanger bolt. Please refer Sikaflex instructions for
use.
Figure 4.2.5
Figure 4.2.6A
Figure 4.2.6B
6) Screw out the top nut of hanger bolt, connect and adjust tin foot position and tighten the top nut with the
recommended torque of 16~20 N•m.
7) Rail, clamps, and panel installation
Please refer to
PV-ezRack® Solar Roof Installation Guide
for steps on installing rails, clamps and PV panels.
The guide also gives our standard engineering spacing of hangar bolts based on site conditions.
Note: Hangar bolt spacings are equivalent to tin feet spacings in the installation guide.