The final filter (4) is the last filtration step and it also spreads the airflow. There is an on/off switch
(D) and a high-voltage indicator (E) on the control panel (see fig. 2.3). Please contact your dealer if
the alarm light is illuminated. Regularly check the functioning of the indicator when using the
product, since it indicates that the electrostatic filter is properly charged.
Figure 2.3
When the product produces a crackling sound, then it could be that the collector and/or ionizer are
too dirty and that both need to be cleaned. Switch-off the product with the appropriate switch (D).
Wait for at
least 10 seconds
prior to opening the door that contains the filtration section.
Subsequently, clean the collector and ionisation section using warm water and degreasing agent.
Check for touching collector plates. Consult your supplier if the plates are bent! Repairs shall only
be carried out by JAKKA Group or JAKKA GROUP-authorised staff. Maintenance contracts are available if
required.