Technical and Operations Manual - Fitting Stainless Steel Ioniser Blades 25
Electrostatic Precipitator (ESP)
Filter Unit
Figure 17 -
Ioniser Bar Upper
Ioniser Bar
Upper
Collector Cell
Location and fitting Stainless
Steel Ioniser Blades
Clamping Ioniser Blade
Fitting Stainless Steel Ioniser Blades
7.
Turn the Collector Cell upside down, being careful to keep the Ioniser Blade’s lower
protruding lug located in the Lower Ioniser Bar’s location hole, and carefully bend
the lug down to secure the bottom lug of the Ionizer Blade.
The blade should now be securely attached to the Collector Cell’s Upper and Lower
Ioniser Bars.
8.
Turn the Collector Cell back upright and repeat the steps 5, 6 and 7 above for each
Ioniser Blade until all eight have been securely fitted.
The Collector Cell is now ready to be placed back into the Main Chassis:
1.
Replace the Pre and Post Mesh Filters and replace the Collector Cell back into the
Main Chassis.
Note:
Make sure that the air flow direction arrow, noted in step 3 on page 24, is
pointing in the correct direction.
2.
Close the Main Door and replace and tighten the two Star Knobs making sure that
the Main Door is tightly closed.
3.
Turn the Rotary Mains Isolator Switch to the ‘On’ position.