•  When  the  system’s  tap  is  turned  on,  the  water  sto-

red in the tank flows through a post-filtering stage (R) 

whose  aim  is  the  elimination  of  possible  odours  and 

taste, as well as pH level adjustment (depending on the 

model), which the water may retain before being dis-

pensed.

• Depending on the model, the appliances may have di-

fferent functional and/or safety systems, managed by a 

state-of-the-art electronic module:

• The equipment with a pump (P) control the filling of 

the tank via a pressure switch (HPS). 

ACUSTIC

INDICATION

4. INTERFACE. SYSTEM STATUS.

CONTROLLER PJK-266-B  +  PJK-049
VISUAL INDICATION

BLUE LED

“Power”

GREEN LED

“Water quality detector”

BLUE LED

“Power”

GREEN LED

“Water quality detector”

RED LED

“Leaking sensor/filters”

RED LED

“Leaking sensor/filters”

RED LED

“Leaking sensor/filters”

Electrically powered system.

-

-

-

x1

x1

x2

When the PUSH-button on the front panel is 
pressed, it indicates thet the quality of water 
produced is excellent.
When the PUSH-button on the front panel is 
pressed, it indicates thet the quality of water 
produced is poor.
Carry out the maintenance/change the filters 

immediately. **

A water leak has been detected. Systen bloc-
ked. Remove water from sensor in order to 
start back the unit.

Carry out the maintenance/change the filters 
soon.

The electric/electronic system is not wor-
king properly /has failed*

PUSH

LED

STATUS

MEANING

          -              Led is off 

                -    LED is permanently off 

     LED is on: single flashing

            

            LED is on: double flashing                        Acoustic signals                        Regular acoustic signals

x1

-

-

-

-

-

(*) Contact your service.
(**) In order to guarantee the quality of the produced 
water, the unit will remain blocked after 1 year while 
informing the user that the filters should be replaced. 
If tou detect that the unit is blocked please contact the 
maintenance service to make the appointment and so 
do the maintenance required by the equipment.
(***) Contact your service if, after apening the faucet, 

the unit would find at rest without dispensing water 
using the tap or showing any alarm.
Contact your service if the unit blocks repeatedly due 
to low water pressure and having pressure water on 
the rest of the house without dispensing water using 
the tap or showing any alarm.
When you detect any of the states described above, 
contact with the maintenance service to arrange 

appointment. See the relevant section in Technical 
Manual. 
The beeps are not continous; they last a few seconds 
(10 s.) While maintenance state is maintained it will be 
indicated by LED’s on the panel and acoustic notifica-
tion periodically every 7 hours.

Read troubleshooting section in User Manual. 

x2

• The unit with a pump (PUMP) have a built-in low pressure 

switch to protect the pump against pressure drops from the 

network (LPS). 

• Electronic system for leakage detection (L). When the sys-

tem detects this condition, it blocks the system and emits 

an acoustic signal and a light signal to inform about the 

situation.  The  unit  will  remain  blocked  until  the  leakage 

sensor is dry. 

Summary of Contents for GuTZZI FT

Page 1: ...Ficha técnica Libro de servicio Data sheet Service book 2 4 FT ...

Page 2: ......

Page 3: ...1 MAIN SPECIFICATIONS 2 TECHNICAL SPECIFICATIONS 3 HOW THE EQUIPMENT WORKS 4 INTERFACE SYSTEM STATUS 5 GUARANTEE 6 BOOK OF SERVICE START UP AND MAINTENANCE OF THE SYSTEM 7 SERVICE BOOK USER 14 16 19 19 20 21 23 ...

Page 4: ...ontrol Built in safety mesh PRESSURE CONTROL Protection against pressure drops in the supply network ELECTRONIC ADAPTER Higher safety and efficiency DOUBLE FLOW Higher flow of produced water ENCAPSULATED MEMBRANE Maximum hygiene Easy intallation FLUSHING READY Autoflushing solenoid valve preassembly kit AQUASTOP Automatic leakage sensor INTERFACE The appliance can be configured and adapted to the ...

Page 5: ...ROL Conductivity control of water produced SOUND WARNINGS Acoustic warnings BLOQUEO DE SEGURIDAD Proper maintenance guarantees water quality COMPACT PRESSURE PUMP High efficiency Compact design AUTO DIAGNOSIS Individualized verification for easier components maintenance ...

Page 6: ...eristics of the water to be treated in the membrane outlet These values may vary in function of the type of post filter used by the equipment and or setting of the mixing valve where applicable Technical Information PUMP Control type High pressure switch Inlet solenoid valve Safety lock Low pressure switch Electronic leaking sensor Maintenance notice Water quality control Dimensions mm 410 x 415 x...

Page 7: ...50 60 Hz 24 Vdc Tap type Klein 1 way Production 0 25 lpm Without counter pressure Water to be treated 15 ºHF 200 ppm 20 ºC 2 bar Control and management PJK 266B PJK 049 electronic system Membrane cleaning system Hydraulic diagram IN Stem 3 8 OUT Stem 1 4 OUT Stem 1 4 OUT OUTLET IN INLET IN STEM 3 8 OUT RM 1 4 IN INLET OUT R OUT RO LPS L SI S C P Q T HPS REST G R M ...

Page 8: ...AMÉRICA Pol Ind L Ametlla Park C Aiguafreda 8 08480 L Ametlla del Vallès Barcelona Spain T 902 305 310 F 34 936 934 329 3 HOW THE EQUIPMENT WORKS The mains water to be treated is fed through the equi pment after passing through the pre filtering stage that incorporates a turbidity S and carbon filter C During this filtering stage chlorine its derivatives and other organic substance particles are r...

Page 9: ...is off LED is permanently off LED is on single flashing LED is on double flashing Acoustic signals Regular acoustic signals x1 Contact your service In order to guarantee the quality of the produced water the unit will remain blocked after 1 year while informing the user that the filters should be replaced If tou detect that the unit is blocked please contact the maintenance service to make the app...

Page 10: ... PAM shall be held responsible for any lack of conformity of equipment in relation to its origin identity or appropriateness of the products in accordance with equipment type and end use Taking into account the equipment s characteristics in order for the warranty to cover any lack of conformity the adherence to the installation and working technical conditions which appear in this warranty is ess...

Page 11: ...No Town City State County Post Code Date and signature INFORMATION REGARDING THE EQUIPMENT S APPLICATION Source of water to be treated Public water supply network Other networks RO equipment prior treatment RO equipment entry hardness ºF RO equipment entry TDS ppm RO equipment entry pressure bar RO equipment entry chlorine concentration ppm INSTALLATION PROCESS CONTROL Membrane assembly Sanitation...

Page 12: ...TURE AND STAMP OF AUTHORISED TECHNICIAN MAINTENANCE COMPLETE REPAIR SANITATION OTHERS INITIAL OPERATION TECHNICIAN ORDINARY EXTRAORDINARY WARRANTY STAMP TECHNICIAN ORDINARY EXTRAORDINARY WARRANTY STAMP TECHNICIAN ORDINARY EXTRAORDINARY WARRANTY STAMP TECHNICIAN ORDINARY EXTRAORDINARY WARRANTY STAMP TECHNICIAN ORDINARY EXTRAORDINARY WARRANTY STAMP TECHNICIAN ORDINARY EXTRAORDINARY WARRANTY STAMP 6 ...

Page 13: ...D TECHNICIAN MAINTENANCE COMPLETE REPAIR SANITATION OTHERS INITIAL OPERATION TECHNICIAN ORDINARY EXTRAORDINARY WARRANTY STAMP TECHNICIAN ORDINARY EXTRAORDINARY WARRANTY STAMP TECHNICIAN ORDINARY EXTRAORDINARY WARRANTY STAMP TECHNICIAN ORDINARY EXTRAORDINARY WARRANTY STAMP TECHNICIAN ORDINARY EXTRAORDINARY WARRANTY STAMP TECHNICIAN ORDINARY EXTRAORDINARY WARRANTY STAMP 7 SERVICE BOOK USER Warning t...

Page 14: ...FTGUTZZI2016 FT ...

Reviews: