10
WWW.BBTA.COM.AU
BBT-GEN-3.5KWINV
OPERATION
NOTE:
• The generator has been shipped without engine oil. Fill with oil or it will not start.
• DO NOT tilt the generator when adding engine oil. This could result in overfilling and damage to the
engine
Starting the Engine
NOTE: Before starting the engine, DO NOT connect the electric apparatus.
A. Recoil start
1. Open the fuel tank air vent to the ‘OPEN’ position.
2. Turn the fuel cock lever to the ‘ON’ position.
3. Turn the engine switch to the ‘ON’ or ‘RUN’
position.
4. Turn the choke lever to the ‘ ’ position. Not
necessary if the engine is electric type.
5. Pull the starter handle slowly until resistance is felt.
This is the ‘Compression’ point. Return the handle
to its original position and pull swiftly. Do not fully
pull out the rope. After starting, allow the starter
handle to return to its original position while still
holding the handle. Grasp the carrying handle
firmly to prevent the generator from falling over
when pulling the recoil starter.
6. Warm up the engine.
7. Turn the choke lever back to the operating position.
Not necessary if the engine is electric type.
8. Warm up the engine without a load for a few
minutes.
B. Electric start
1. Open the fuel tank air vent to the ‘OPEN’ position.
2. Turn the fuel cock lever to the ‘ON’ position.
3. Turn the engine switch to the ‘START’ position.
4. Turn the engine switch to the ‘RUN’ position
5. Warm up the engine without a load for a few
minutes.
C. Remote start
1. Open the fuel tank air vent to the ‘OPEN’ position.
2. Turn the fuel cock lever to the ‘ON’ position.
3. Turn the engine switch to the ‘RUN’ position.
4. Click remote switch to the ‘ON’ position.
5. Warm up the engine without a load for a few
minutes.
All manuals and user guides at all-guides.com