Command
Function
Feedback Example
[xx]=00~08,
xx=01~08 is the number of output
port, if the xx=00, it means all output
ports.
OUT 03 HDCP PASSIVE!
OUT 04 HDCP PASSIVE!
OUT 05 HDCP PASSIVE!
OUT 06 HDCP PASSIVE!
OUT 07 HDCP PASSIVE!
OUT 08 HDCP PASSIVE!
HDCP[xx]BYP.
Output HDCP follows input HDCP.
Input has HDCP, output is HDCP1.4.
Input doesn’t have HDCP, output is
without HDCP.
[xx]=00~08,
xx=01~08 is the number of output
port, if the xx=00, it means all output
ports.
OUT 01 HDCP BYPASSS!
OUT 02 HDCP BYPASSS!
OUT 03 HDCP BYPASSS!
OUT 04 HDCP BYPASSS!
OUT 05 HDCP BYPASSS!
OUT 06 HDCP BYPASSS!
OUT 07 HDCP BYPASSS!
OUT 08 HDCP BYPASSS!
8.2.7
EDID Management
Command
Function
Feedback Example
EDIDMInit.
Restore the factory default EDID data
for each input.
All Input EDID Set Default! System
Initialization......
1111
PT-MA-HD88DA
V1.0.0
Power ON!
Front Panel UnLock!
EDIDUpgrade[xx].
Upgrade EDID via Serial Port
[xx]=00~08
xx=01~08 is the number of the
port(able EDID user-defined for
corresponding HDMI input), if the
xx=00, it means all ports(able EDID
user-defined for all HDMI inputs).
Note:
EDID user-defined can be used
once, if switch to another EDID or exit, it
will not be saved.
File size: 256
Baud rate:115200bps
Quired time: About 0 second
Please wait...
Send Completed
!
User Define EDID