Operation
Radfire UV Unit
• Prior to performing any work on the UV steriliser system, always disconnect the
power supply.
Warning: Do not look directly into ultraviolet rays emitted from the UV lamp as
they will cause serious burns to unprotected eyes.
• The treated water will seem warm for a short period at first flow. This is because
the UV lamp emits heat. When turning on a tap, let the water run for a short time to
purge any warm water.
Lamp Ballast Operation
Press the mode button to cycle the display between lamp life remaining and total
running days.
Press and hold the silver button for 15 seconds to reset lamp life timer or until
'reset' appears on the screen.
To silence the 'lamp life end' alarm for 7 days, press and hold on the silver button
until 'delay' appears on the screen.
Lamp Ballast Specifications
AC 240V | 50Hz
Lamp Power: 35W~95W
Lamp Current: 0.8A~0.9A
Ambient Temperature: 4~40°C
Lamp Rated Life: 365 days
Caution: Ground the ballast casing to avoid possible high voltage shock hazard
Operation
• Allow two minutes for the UV lamp to reach full intensity before using the outlet
water.
• On a new installation where no other form of sterilisation has been in use, we
recommend flushing the pipe work with a suitable sanit iser such as TankSafe
™
(for
dosage refer to TankSafe
™
product instructions). This solution should be left in the
pipework for at least an hour and preferably overnight.
The sanitising solution can be added into the water tank or if necessary added as a
shock dose into the bowl of the filter housing of the HybridPlus and slowly flushed
through the piping. If added as a shock dose the system and pipework should be
rinsed thoroughly by opening a downstream tap.