HYBRID M1 | Filtration & Ultraviolet All-in-One Undersink Unit
Operation
5. Install new cartridges and replace housing screwing them up HAND TIGHT ONLY.
Sediment filter is on the inlet side and chemical on the outlet side.
6. Restore water supply & check for leaks, rectifying them, if any, before leaving the
unit.
After installing cartridges flush unit for 5 - 10 minutes.
Cleaning Quartz Sleeve
To ensure high sterilising rate with best water quality, check sleeve regularly (about
every 3 months depending on quality of water source). To see whether there is dirt or
substances gathered. Clean with alcohol based cleaner if necessary.
Quartz Sleeve Maintenance Procedure
1 Unplug the power supply. Remove UV lamp before taking out the quartz sleeve
and pour out water. Turn counterclockwise the aluminium nut both sides of the
chamber and extremely gently to remove the quartz sleeve.
2 Soak a piece of cloth in vinegar or citric acid to clean the quartz sleeve.
3 Put the quartz sleeve back into the stainless steel chamber and make equal
distance at both sides of the chamber.
4 Dampen the seal O-Ring and end of the quartz sleeve then turn clockwise the
aluminium nuts with hands tightly.
5 Check all connections to prevent leakage.
6 Insert UV lamp into stainless steel chamber and put on the rubber cap to complete
the cleaning.