background image

Wuhan Raycus Fiber Laser Technologies Co., Ltd

U

ser Guide of 1000W CW laser

Figure 15 Modulation—sequence diagram

Figure 16 Gate mode –sequence diagram

4.7.6 Red Light Control

Turn on the rocker switch, the green "POWER" indicator light is on, wait for

20s, the laser enters the red-light external control mode, and a high level of 5-24V
is given before the 17-20 pin. If red light internal control is selected on the host
computer, you can use the host computer to click "red light on" to turn on the red
light.

35

Summary of Contents for RAYCUS RFL-C1000W+H

Page 1: ...RAYCUS RFL C1000W H...

Page 2: ...11 2 7 Specifications 12 3 Installation 13 3 1 Dimensions 13 3 1 1 Overall dimensions of RFL C1000 cutting laser 13 3 2 Size and installation of output optical cable 14 3 2 1 RFL C1000 Output Optical...

Page 3: ...ect 4 6 in sequence 31 4 7 3 External control mode sequentially connected to 4 6 32 4 7 4 AD Mode 33 4 7 5 controlling time series chart 34 4 7 6 Red Light Control 35 4 8Turning off the laser 36 5 Com...

Page 4: ...l injury or death CAUTION Describes a hazard that leads to a minor personal injury or product damage 1 2 Laser Safety Grade This series of lasers are classified as a high power Class 4 laser instrumen...

Page 5: ...e range of laser wavelengths Please do not directly look at the fiber delivery cable connector when laser is powered on 1 3 Security Identifiers Raycus CW Fiber Lasers have different locations of safe...

Page 6: ...the end of the collimator assembly can burn the lens CAUTION DO NOT emit laser when the protective cap is not removed otherwise the lens or crystal will be damaged 1 5 Electrical Safety 1 Make sure th...

Page 7: ...nment 3 If this device is used in a manner not specified in this document the protection provided by the device may be impaired and the warranty will be voided 4 There are no user serviceable parts eq...

Page 8: ...ti reflection Capacity High modulation frequency and editable waveform Applications Welding 5G Infrastructure 3D printing Laser research 2 2 Model description Raycus continuous wave laser includes 100...

Page 9: ...imal safety Nevertheless in order to prevent the occurrence of unpredictable circumstances during the transportation please inspect all packaging once receiving the delivery If you find any evidence o...

Page 10: ...kW 3 5 Installation Environment Flat and no vibration Ambient Temperature 10 40 Relative Humidity 70 Warning 1 Make sure the product is properly grounded before use 2 The laser output head is connecte...

Page 11: ...23 24 30 4 6 10 5 15 18 5 21 5 24 26 28 29 35 8 5 15 19 5 23 26 28 5 31 33 34 40 13 20 24 27 5 31 33 5 36 38 39 Laser operating temperature range 2 6 Attentions 1 Make sure that the correct voltage a...

Page 12: ...5hrs AmbientTemp 25 ModulationFrequency Hz 50 50 000 NominalOutputPower RedGuideLaserPower mW 0 1 1 OpticalOutputCharacteristicsofQBHhead BeamQuality M 1 3 BPP 2 3 mm mra d NominalOutputPower CoreFibe...

Page 13: ...Ltd User Guide of 1000W CW laser 3 Installation 3 1 Dimensions 3 1 1 Overall dimensions of RFL C1000 cutting laser Figure 2 shows the external dimensions of the RFL C1000 laser Figure 2 a Front view...

Page 14: ...n of output optical cable Raycus continuous wave fiber laser uses different laser output cables according to different laser models 3 2 1 RFL C1000 Output Optical Cable The output cables of Raycus RFL...

Page 15: ...er the output fiber cable is installed in the processing equipment Before installing the output cable in the processing head the lens of the output cable must be inspected If the lens is dirty it must...

Page 16: ...peration 3 Other cooling system requirements Check the entire water system and joints for leaks when starting the cooling system the first time The external water pipe must be installed and connected...

Page 17: ...ble 5 and the earth line is connected and ensure the earth line is firmly connected 3 Connect the power cable and control cable to the product when power supply is OFF 4 Connect the cooling system to...

Page 18: ...tate such as transport and storage The minimum bending diameter should not be less than 30cm when the laser is working CAUTION All the cables can only be connected when power supply is off Hot plug ma...

Page 19: ...the official website of Raycus to download the new version of the upper computer software and upper computer software instruction manual Web http www raycuslaser com index php index show tid 53 html...

Page 20: ...rt the quick plug water pipe with an outer diameter of 16 into the pagoda head and fasten it with a clamp to connect the laser to the circulating cooling water 5 Interface Laser external control inter...

Page 21: ...ologies Co Ltd User Guide of 1000W CW laser 4 3 Power Connection Before connecting the AC power supply please check whether the laser model and the AC power supply provided are consistent with those l...

Page 22: ...wn N Neutral blue PE Protective earth wire yellow green Note Insert the plug at the end of the power cord into the socket marked AC INPUT on the rear panel Note that the plug has anti reverse connecti...

Page 23: ...emergency stop Short circuit 12 Analog Analog input External analog quantity setting 0 10V 0V 0 10V 100 10mA 13 Laser Power Analog output Optical power signal output 0V 0 3 3V 100 10mA 14 AGND Analog...

Page 24: ...5 24V 5V 24V 100mA other NC Not allowed to connect Please check the level of the control signal to ensure compliance Exceeding voltage or voltage fluctuations may damage the laser Please ensure that...

Page 25: ...S 232 control interface are as follows Table 10 RS 232 interface configuration parameters Parameters Set up Baud rate 9 600 Data bits 8 Stop bit 1 polarity None Flow control None Figure 9 RS 232 seria...

Page 26: ...Raycus PC software click Session RS232 or Ethernet to make the host computer communicate with the laser and then click Tool Laser IP Set to enter the laser IP address setting Second Step The default p...

Page 27: ...t network connection on the PC side select Use the following IP address and manually assign the IP address The PC side IP address must be on the same network segment as the laser IP address and assign...

Page 28: ...position to fix it with screws 2 Remove the protection cap of the output head use strong light to check if there is dust on the lens of the output end If so please clean it before use and then cover...

Page 29: ...the rocker switch is off All electrical connections must be completed before the laser is powered on 1 Turn on the chiller and check the water pipe for leaks If there is no leakage turn off the chille...

Page 30: ...ing diagram Figure 11 Wiring diagram in RS 232 mode Note In the above mode the upper computer of Raycus should be used to modify the mode turn off the external red light control external light out ena...

Page 31: ...it initialization is completed 3 Turn off all external control mode of the laser turn off external control of red laser external light emitting enable external AD and modulation mode 4 Set the power o...

Page 32: ...trolled by the modulation signal provided by the user from the external MOD interface For the timing diagram see 4 7 5 Control timing Figure Gate mode When the duty cycle of the laser s internal frequ...

Page 33: ...ace to issue the shutter open command enable light 9 The On Off of the laser is controlled by the modulation signal provided by the external mod interface Shutdown the laser please refer to 4 8 4 7 4...

Page 34: ...chnologies Co Ltd User Guide of 1000W CW laser Raycus User Guide Using the Product 33 4 7 5 controlling time series chart Figure 13 Standalone mode Continuous sequence diagram Figure 14 Standalone mod...

Page 35: ...7 6 Red Light Control Turn on the rocker switch the green POWER indicator light is on wait for 20s the laser enters the red light external control mode and a high level of 5 24V is given before the 17...

Page 36: ...he laser Please turn off the laser in the following sequence 1 Turn off the laser output enable 2 Turn off the rocker switch 3 Turn off the chiller 4 If the laser is not equipped with air conditioner...

Page 37: ...ent software interface as shown in Figure 17 The laser will give an alarm in the case of abnormal internal temperature abnormal output power abnormal power supply abnormal condensation etc Figure 17 m...

Page 38: ...panel of the laser has been pressed before powering on Solutions When this alarm occurs please power off the laser and make the light enable button pop up and then power on the laser again to cancel t...

Page 39: ...he laser is emitting light Solutions Restart the Device If this error continues to occur please contact Raycus ACDC1 Alarm Instruction AC DC1 Alarm Laser power supply out of work or sudden power disco...

Page 40: ...ctual water temperature of the water is too low In addition a low ambient temperature may also cause a low temperature alarm when the laser is cold Please wait until the water temperature of the water...

Page 41: ...under warranty Raycus reserves the right to issue a credit note for any defective products produced in normal conditions 6 2 Limitations of Warranty The warranty does not cover the maintenance or rei...

Page 42: ...cus personnel Please contact Raycus as soon as possible when problems under warranty about maintenance happened to the product The product returned with permission should be placed in a suitable conta...

Page 43: ...www purelogic ru 7 495 505 63 74 7 473 204 51 56 394033 160 149 info purelogic ru 8 800 555 63 74 800 1700 800 1600...