Wuhan Raycus Fiber Laser Technologies Co., Ltd
U
ser Guide of 1000W CW laser
After installing and arranging the output optical cable, remove the
protective cap, and check whether the output lens is clean again, and then
install the output head;
4) Connect the laser cooling water pipe;
5) Connect the control line and power supply according to the control mode.
4.6 Start operation sequence
Make sure the rocker switch is off. All electrical connections must be completed
before the laser is powered on.
1) Turn on the chiller and check the water pipe for leaks. If there is no
leakage, turn off the chiller and wait for the laser to turn on.
2) Close the rocker switch on the rear panel and wait for the laser to power
on and perform a self-test.
Note: When the working environment temperature and relative humidity are within
the dew point area (blue) in Table 4, for RFL-C100 to C3000 type lasers, please
improve the working environment of the laser to avoid damage to the laser due to
condensation.
29
Summary of Contents for RAYCUS RFL-C1000W+H
Page 1: ...RAYCUS RFL C1000W H...