SECTION 3 – INSTALLATION AND OPERATION
Inspection
Remove the compressed air dryer or adsorber from the shipping carton. Inspect the unit
for any visible shipping damage. If shipping damage is noted, immediately contact the
responsible carrier to file a freight claim to be reimbursed for the repair.
Location
Desiccant-type compressed air dryers and adsorbers should be installed in the coolest
practical location that is not subject to freezing temperatures. An acceptable
temperature range is between 40
o
F (4
o
C) and 125
o
F (52
o
C). Although the unit will
operate at higher temperatures, the operating life of the components will decrease at
temperatures much above 85
o
F (29
o
C). Bear in mind that abrasive dust and chemicals
will also reduce the life of any electromechanical device.
Mounting
All of the models covered by this instruction manual can be wall-mounted using the
brackets provided. Products should be mounted with the desiccant towers in a vertical
orientation for best results. Be careful to not overtighten purge mufflers.
NOTE: Dimension “A” can be 6, 9, 12, or 20,
depending on model. Dimensions in inches.
FIGURE 4: DIMENSIONS OF PHF, PCDA, PHCA, AND PCME MODELS