PUREGAS, LLC
P200W Series Dehydrator User’s Guide
Page 63 of 82
P012026 – Rev. F
9.2 Measuring Incoming Voltage
9.2.1
Power the Dehydrator
OFF
(Section 8.3 ).
9.2.2
For P200W and P208W models:
9.2.2.1
Disconnect the DC
Power Harness from the
Power Port on the back
of the Dehydrator.
9.2.2.2
Place Voltmeter
probes inside the DC
Power Harness
connector socket:
RED
probe to
WHITE
wire
BLACK
probe to
BLACK
wire
The voltage should measure
24 VDC
for the P200W model and
48
VDC
for the P208W model.
9.2.2.3
Re-connect the DC Power Harness to the Power Port on the back of
the Dehydrator.
WARNING!
Extreme care should be exercised to avoid contact with live
electrical circuits.
It is highly recommended that you remove all
jewelry before performing any procedures.