1:

 Feed the coaxial cable coming from the X-Shaped Power Connector through the knurled nut, 2" canopy and cord grip 

    assembly respectively.

2:

 For the 4" canopy, feed the coaxial cable through the cord grip of the canopy.

NOTE: 

If cable is curled or kinked, straighten by holding between the shaft of a screwdriver and thumb and pulling the cable 

through (see inset).

2

CORD
GRIP

NOTE: 

Omit this section if the connector does not come with a 2" or 4" Canopy. Refer to the other surface mount power canopy 

instructions provided with the product.

Section Two: Installing the Canopy

D

CORD GRIP
ASSEMBLY

COAXIAL
CABLE

1

KNURLED
NUT

2" CANOPY

4" CANOPY

COAXIAL
CABLE

2

4:

 Secure the channel by tightening the four #4-40 set screws 

    using a 0.05" Allen wrench.

5:

 Repeat steps 2 through 4 for the other ends of the X-Shaped

    Power Connector.

6:

 Install the lens and optional louver to the assembled 

    channels (refer to the instructions provided with the 
    channel).

C

3: 

Use the 18AWG hole of the wire stripper to remove 1-3/8" 

    of the outer insulation to expose the braided wire.

4:

 Use the 18AWG hole of the wire stripper to remove 1" of 

    the braided wire making sure not to nick the inner wire 
    insulation.

5:

 Use the 20AWG hole of the wire stripper to remove 1/8" of 

    the inner insulated wire.

BRAIDED 
WIRE

INNER
INSULATION

BARE
WIRE

1/8"

OUTER
INSULATION

1"

3/8"

COAXIAL CABLE

E

COAXIAL
CABLE

3

4

WIRE
STRIPPER

5

NOTE:

 Scan the QR Code to watch the video clip of 

the following steps or visit 
https://www.PureEdgeLighting.com/video_feed/
installation_cxc_connector

#4-40 SET
SCREW

4

5

5

5