Whisper 30 integral Handbook
5.0 How to use the system
5.1 Filling and starting the system.
Step1 Place the Sample Valve in Pos. SAMPLE and guide the hose to a drain.
Step 2 Open the Sea Cock and let water flow into the system.
Step3 We recommend bleeding the system carefully.
Step 4 Start the system and open the bleed Valve at the red pre-filter. When water is coming out, close the
valve.
If you don’t see water coming out at the overboard outlet within a Minute, stop the
system and check the position of the valves.
Step4
If everything is fine and the overboard brine flow is free of air you can watch the pressure indicators.
The low pressure at the panel should read between 8 to 10 Bar and the high pressure Gauge at the ETD
should read in normal seawater 45-55 Bar. If you test the unit in brackish water the pressure is lower.
Step 5
ONLY FOR COMPACT MODELS
. Watch the Quality Monitor. After 1-2 Minutes, the water quality should
be below 500 PPM and the system produces water into the tank.
Step 6
NOTE!!
If you use the system for the first time or you start the system after having done long term storage, drain
the product water for about 5 minutes to allow all chemicals drained.
Step 7 Check the product water either with a handheld tester (Option) or just taste it.
Step 8 If you find the water quality good, stop the unit and place the sample valve to Pos. Tank. Start the unit.
Now the product water is produced into the tank.
Step 9 Check all connections for possible leaks.
---------The unit is now ready for use ---------
11
Summary of Contents for Whisper 30
Page 15: ...Whisper 30 integral Handbook Preservation Configuration 12...
Page 20: ...Whisper 30 integral Handbuch 7 0 Flow Diagram Normal Operation 17...
Page 22: ...Whisper 30 Integral Handbook 9 0 ETD Exploded Parts View 19...
Page 23: ...Whisper 30 Integral Handbook 9 1 ETD Parts 20...
Page 24: ...Whisper 30 Integral Handbook 9 1The John Guest System 21...